Refrigerant Pressure Switches Lps - Hps - Pv; Compressor Crankcase Heater - Beko DRYPOINT RA CT Series Instructions For Installation And Operation Manual

Compressed air refrigeration dryer
Table of Contents

Advertisement

11.10 Refrigerant pressure switches LPS – HPS – PV
To ensure the operational reliability and the protection of the dryer, a series of pressure switches are installed in the
gas cycle.
LPS : Low-pressure guard on the suction side of the compressor, which is triggered when the pressure drops below
the predetermined value. The values are reset automatically as soon as the nominal conditions are re-
established.
Calibrated pressure :
HPS : The high-pressure control unit on the discharge side of the compressor is activated when the pressure
exceeds the predetermined value. It has a manual reset button on the control itself.
Calibrated pressure :
PV :
Fan control pressure switch which is installed on the discharge side of the compressor. It keeps the
condensation temperature and pressure constantly in the range of the preadjusted limit values
Calibrated pressure :

11.11 Compressor crankcase heater

At low temperatures, the oil can more easily intermix with the refrigerant gas. When the compressor starts, oil can be
drawn into the refrigeration cycle, leading to "hydraulic shocks".
To prevent this, a resistance heater is installed in the suction side of the compressor. When the system is connected
with the electric mains and the compressor is idle, the heater will keep the oil at the correct temperature.
This heater is controlled via a temperature switch which prevents the overheating of the oil.
Note: The heater must be connected to the mains at least a few hours prior to the start-up of the refrigerating
compressor.
DRYPOINT® RA CT 200-500 NA 3PH
R 134.a
Stop 10.2 psig (0.7 barg) - Restart 24.7 psig (1.7 barg)
R 407 C
Stop 24.7 psig (1.7 barg) - Restart 39.2 psig (2.7 barg)
R 134.a
Stop 290 psig (20 barg) - Manual reset P<203 psi (P<14 bar)
R 407 C
Stop 435 psig (30 barg) - Manual reset P<334 psi (P<23 bar)
R 134.a
Start 160 psig (+7.25 / -0 psi) [11 barg (+0.5 / -0 bar)]
Stop 116 psig (+0 / -7.25 psi) [8 barg (+0 / -0.5 bar)]
R 407 C
Start 261 psig (+7.25 / -0 psi) [18 barg (+0.5 / -0 bar)]
Stop 203 psig (+0 / -7.25 psi) [14 barg (+0 / -0.5 bar)]