Beko DRYPOINT RA VSD Series Instructions For Installation And Operation Manual page 30

Compressed air refrigeration dryer
Table of Contents

Advertisement

Technical description
ID
BT1 probe - Dew point temperature
W1
BT1 probe - Dew point temperature
W2
BT2 probe - Inlet air temperature
W3
BT3 probe – Compressor suction temperature
W4
ELD condensation drainer
W5
W5
ELD condensation drainer
Dn nn
Specific Warnings - Consult your dealer
W6
BT4 probe – Refrigerant fluid temperature
W7
High compressor supply side temperature
(supply over normal limits but within safe limits)
BLP transducer - Evaporation pressure
W8
BHP transducer - Condensation pressure
W9
BHP transducer - Condensation pressure
W10
BT5 probe - Room temperature
W11
BT5 probe - Room temperature
W12
BT5 probe - Room temperature
W13
BT2 probe - Inlet air temperature
W14
BT2 probe - Inlet air temperature
W15
NOTE: Refer to the "Troubleshooting" section for possible causes and solutions to the Warning.
30
Warning description
Low temperature
High temperature
Fault
Fault
Malfunction
Scheduled service
Time expired
High pressure
Low Pressure
High pressure
Low temperature
High temperature
Fault
Low temperature
High temperature
Set
Delay
T1 < -1.0°C
3 min
T1 > HdA
Parameter
parameter
Hdd
Fault
Flag
probe
immediately
Fault
Flag
probe
immediately
Opening
20 min
Digital Input 5
-
-
Parameter
Flag
SrV
immediately
T4 > 100.0°C
60 sec
R407C
LP > 6.8 barg
6 min
R134.a
LP > 5.0 barg
Variable
10 min
Variable
10 min
T5 < 0.0°C
5 min
T5 > 45.0°C
5 min
Fault
Flag
probe
immediately
T2 < 10.0°C
5 min
T2 > 70.0°C
5 min
DRYPOINT® RA VSD 800-2500
Reset
T1 ≥ 0.0°C
Parameter
HdA-1K
Reset
probe
Reset
probe
Closing
Digital Input 5
-
Timer
reset
T4 < 95.0°C
R407C
LP ≤ 6.8 barg
R134.a
LP ≤ 5.0 barg
Variable
Variable
T5 ≥ 1.0°C
T5 ≤ 42.0°C
Reset
probe
T2 ≥ 11.0°C
T2 ≤ 65°C