Cooling Operation - Fujitsu AGU12RLF Service Instruction

Hide thumbs Also See for AGU12RLF:
Table of Contents

Advertisement

1. COOLING OPERATION

A sensor (room temperature thermistor) built in the indoor unit body will usually perceive
difference or variation between a set temperature and present room temperature, and
controls the operation frequency of the compressor.
* If the room temperature is 4°F(2°C) higher than a set temperature, the compressor operation
frequency will attain to maximum performance.
* If the room temperature is 5°F(2.5°C) lower than a set temperature, the compressor will be
stopped.
* When the room temperature is between +4°F(+2°C) to -5°F(-2.5°C) of the setting temperature,
the compressor frequency is controlled within the range shown in Table 1.
However, the maximum frequency is limited in the range shown in Fig. 1 based on the
fan speed mode and the outdoor temperature.
( Table 1 : Compressor frequency range )
AOU9RLFF
AOU12RLFF
AOU15RLFF
When the compressor operates for 30 minutes continuously at over the maximum frequency ,
the maximum frequency is changed from Maximum Frequency
( Fig.1 : Outdoor temperature zone )
Outside air
temperature
A zone
93°F
(34°C)
B zone
86°F
(30°C)
C zone
66°F
(19°C)
D zone
50°F
(10°C)
E zone
32°F
(0°C)
F zone
Minimum
Air flow
frequency
Upper & Lower
10rps
Upper
Upper & Lower
12rps
Upper
Outside air
temperature
97°F
(36°C)
90°F
(32°C)
70°F
(21°C)
54°F
(12°C)
36°F
(2°C)
Maximum
Maximum
frequency
frequency
76rps
57rps
56rps
91rps
to Maximum Frequency .
( Table 2 : Limit of maximum speed based on outdoor temperature )
AOU9/12RLFF
Outdoor
temp. zone
A zone
Upper & Lower
air flow
B zone
C zone
D zone
E zone
F zone
A zone
Upper air flow
B zone
C zone
D zone
E zone
F zone
AOU15RLFF
Outdoor
temp. zone
A zone
Upper & Lower
air flow
B zone
C zone
D zone
E zone
F zone
A zone
Upper air flow
B zone
C zone
D zone
E zone
F zone
01-01
Indoor fan mode
Hi
Me
Lo
Quiet
76rps
45rps
37rps
29rps
76rps
45rps
37rps
29rps
76rps
45rps
37rps
26rps
43rps
35rps
26rps
20rps
51rps
37rps
31rps
22rps
51rps
37rps
31rps
22rps
76rps
45rps
37rps
29rps
76rps
45rps
37rps
29rps
76rps
45rps
37rps
26rps
43rps
35rps
26rps
20rps
51rps
37rps
31rps
22rps
51rps
37rps
31rps
22rps
Indoor fan mode
Hi
Me
Lo
Quiet
91rps
44rps
34rps
24rps
91rps
44rps
34rps
24rps
72rps
44rps
34rps
24rps
52rps
30rps
21rps
18rps
62rps
34rps
27rps
19rps
62rps
34rps
27rps
19rps
91rps
44rps
34rps
24rps
91rps
44rps
34rps
24rps
72rps
44rps
34rps
24rps
52rps
30rps
21rps
18rps
62rps
34rps
27rps
19rps
62rps
34rps
27rps
19rps

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Agu9rlfAgu15rlfAou9rlffAou12rlffAou15rlff