1 BASIC INFORMATION About the Manual This user manual includes interface mode settings, function settings (lighting, keyboard type and factory reset, etc.), symbology settings, exposure optimization in special scenes, and data format editing functions. If you need to change the function you need, scan the corresponding configuration code below.
Interface 1.4.1 USB Cable Connection 1. Insert the RJ45 interface (crystal head) of the USB data cable into the rear of the scanner, there is a crisp "click" sound, and the connection is normal. 2. Connect the USB interface of the USB data cable to the host device. 1.4.2 RS232 Cable Connection 1.
2 System Settings Factory Default Read the "Factory Default" barcode will restore all the properties of the scanner to the factory state. You are most likely to use this barcode when: Scanner setting are incorrect. Eg: barcode cannot be read. You forgot what setting you made on the scanner.
Recover the User Default Setting Restore the system setting state to the last saved user default setting state. The scanner will restart automatically after setting. Restore User Configuration Interface Mode 2.6.1 USB HID Interface When the data cable with USB interface, after read the “USB HID” barcode, scanner will be set to the "USB Keyboard"...
Page 9
2.6.1.2 USB Transmission Delay The USB Transmission Delay can be set to four gears from 0 to 3. If the host will lose characters, the delay can be increased. USB Transmission Delay-0ms USB Transmission Delay-1ms USB Transmission Delay-2ms USB Transmission Delay-3ms 2.6.1.3 Emulate Keyboard When the emulate keyboard input character is enabled, the character will be sent through the numeric keypad, ignoring the national keyboard layout setting;...
Page 10
Disable the emulate keyboard front zero 2.6.1.4 Keyboard Language Country Type When the barcode scanner is used as a keyboard input device by default, some characters are different in different countries, and different national languages need to be set. The keyboard defaults to the US language.
Page 11
El Salvador Japan Sierra Leone Turkey Hungary Thailand Vietnam The Czech Republic Slovakia Russia(CP866) Arabic...
Page 12
Portugal BRAZ_ABNT--Brazil Swiss GERMAN_QWERTZ--German keyboard Swiss FRENCH_QWERTZ French keyboard Portugal...
Page 13
2.6.1.5 Keyboard Mode Encoding Format The keyboard mode can output Chinese, traditional Chinese, Korean, etc. Since the third-party software uses different encoding, the scanner needs to switch to different encoding formats, please scan the corresponding configuration code as required. *Default For "writing board, Word”...
Page 14
Disable BIG5(Traditional Chinese) BIG5(Traditional Chinese) 2.6.1.6 Ctrl+X Mode Send After this function is enabled, the control characters from 00 to 1F in the ASCII code table will be output by the combination of CTRL+X. For the corresponding relationship between the specific ASCII value and the control function keys, see the attached table.
PrtScn CTRL+ R Delete CTRL+ S Save Tab+shift CTRL+ T CTRL+ U CTRL+ V Paste CTRL+ W CTRL+ X CTRL+ Y CTRL+ Z CTRL+ [ CTRL+ \ CTRL+ ] CTRL+ ^ CTRL+ - Delete 2.6.2 USB COM Interface After the scanner of the USB interface is set to "USB COM", the data will be transmitted to the host through the serial port;...
Page 16
RS 232(TTL 232) 2.6.3.1 RS232 Baud Rate The baud rate is the number of digits transmitted per second in serial port communication. The baud rate used by the scanner and the data receiving host must be consistent to ensure the accuracy of data transmission.
Page 17
115200 2.6.3.2 Data Digit Can choose to transmit 7 or 8 digits of data, please make sure that the data digits of the scanner are consistent with those of the data receiving host. 7 Digits *8 Digits 2.6.3.3 Stop Digit The stop digit is located at the last part of each byte transmitted, and is used to mark the completion of the transmission of this byte to start receiving the next byte of data.
Page 18
2.6.3.4 Check Digit Setting The scanner can choose different parity check character types in the process of using the serial port transmission, but it must be consistent with the parity check character type of the host. O(Odd check) S(Fixed value 0) E(Even check)...
Page 19
2.6.3.5 Serial Port Encoding Output Format Serial Port Output UTF-8 Serial Output NOT UTF-8 Serial Port Output CP932 *Serial Output Chinese Serial Port Output according to Barcode Content...
Working Mode In this section, you can change the reading mode of the device, you only need to scan the corresponding setting code according to your needs. 2.7.1 Reading Mode Manual Mode (Trigger On/OFF) *Manual Mode(Trigger ON/OFF) Automatic Mode: After power on, it has been in the state of reading codes. Pressing and releasing the button can briefly switch the scanner between manual and automatic states.
Auto Sense Mode: The scanner enters the induction mode, which can be used with a stand. When an object passes through the scanning window, the scanner will be awakened, the fill light will be lit, and the code will be read. When the decoding time is exceeded, the fill light is turned off. Auto Sense Mode 2.7.2 The Same Barcode Delay The same barcode delay only takes effect in automatic mode.
2.7.3 Barcode Reading Timeout *15 S 30 S 60 S 120 S 180 S 200 S 2.7.4 Autosense Sensitivity settings Sensitivity is 15 classes (B67A61 to BA67A615), class 1 highest, class 15 lowest. Class 1 Class 2 Class 3 Class 4...
4.2KHz Silent 2.10 Vibration Setting Enable *Disable 2.11 Output Setting In this chapter, you can configure the output of the device, including carriage return/line feed, serial port encoding setting, setting barcode length, removing barcode digits (remove/keep from beginning and ending), and multi-countries keyboard switching settings, etc. You only need to read the barcode according to the requirements.
2.11.2 Case Conversion Letter conversion: when outputting barcodes with letter content, you can configure the output result to be all uppercase or all lowercase. For example: the barcode content is ab12DE, if you scan the "all uppercase" barcode, the output result will be AB12DE;...
Remove digits from Ending: "B6BE6X" (X is the number of digits to remove. If the last number is 1, it means remove one digit; if it is 2, remove two digits; if it is 0, it is not removed.) Remove 1 digit from Ending 2.11.4 Keep Data from start/end You can only choose to keep the beginning or ending digit, but not both.
3 Barcode Symbology Configuration This chapter can configure the Barcode Symbology Configuration of the device, including barcode enable/disable, check enable/disable, check output enable/disable, etc. Barcode Configuration Quick Setting of Barcode Enable/Disable Setting Enable All Symbology Disable All Symbology Enable All 1D Symbology Disable All 1D Symbology Enable All 2D Symbology Disable All 2D Symbology...
Barcode Length Setting The barcode length setting code can be edited freely with barcode software, and CODE128 can be selected. For example, the minimum length setting of Telepan is ^3B76E61, 1 means that the barcode with the minimum length of 1 digit can be read, and the maximum length setting code is ^3B77E6255, which means the barcode with the maximum length of 255 digits can be read.
Page 31
Code 11 Length Limit The min. Length of Code 11 is 1 digit The max. Length of Code 11 is 255 digits Codeabar Length Limit The min. Length of Codeabar is 1 digit The max. Length of Codeabar is 255 digits Interleaved25 Length Limit The min.
Page 32
Code 93 Length Limit The min. Length of Code 93 is one digit The max. Length of Code 93 is 255 digits Code 39 Length Limit The min. Length of Code 39 is one digit The max. Length of Code 39 is 255 digits Industrial 25 Length Limit The min.
Page 33
MSI Length Limit The min. Length of MSI is one digit The max. Length of MSI is 255 digits RSS-expend(GS1 DataBar Expanded) Length Limit The min. Length of RSS-expend is one digit The max. Length of RSS-expend is 255 digits QR Code Length Setting The minimum length of the QR code can be set to 1~255 (the minimum length is 1, the maximum length is 255) , 67EE6X (X represents the length of the barcode)
Airline 2 of 5(Standard 2 of 5/IATA 2 of 5) Enable *Disable Aztec Code Enable *Disable Aztec Code Direct and Reverse Color *Regular Both 3.5 Codabar *Enable Disable Codabar Check *Disable Check...
Enable check and output check character Enable check but not output check character Codabar Stop Bit Enable output beginning & ending character *Disable output beginning & ending character Codabar Direct and Reverse Color *Regular Both 3.6 Codablock A Enable *Disable...
3.12 Code 93 Enable *Disable Code 93 Direct and Reverse Color *Regular Both 3.13 Composite To enable this symbology, both Micro PDF and RSS-14 must be enabled at the same time. Enable *Disable 3.14 Data Matrix Code Enable *Disable...
Matrix DM Enable Matrix DM *Disable Matrix DM Lattice DM Enable Lattice DM(DPM) *Disable Lattice DM(DPM) Data Matrix Direct and Reverse Color *Regular Both 3.15 DOT-CODE Enable Disable DOT-CODE Direct and Reverse Color Regular...
Both 3.16 EAN/UPC *Enable Disable EAN/UPC Direct and Reverse Color *Regular Both EAN/UPC Two-digits Additional Code Enable *Disable EAN/UPC Five-digits Additional Code Enable *Disable EAN/UPC Additional Code that must be recognized Enable...
3.20 GS1 DataBar Limited Enable *Disable 3.21 GS1 DataBar Omnidirectional Enable *Disable 3.22 HANXIN Enable *Disable 3.23 Hong Kong 2 of 5(China post) Enable *Disable Notice: When reading a postal, all other postal need close.
3.24 Interleaved 2 of 5 *Enable Disable Interleaved 2 of 5 Check Open check *No check Open check and transmit check character Interleaved 2 of 5 Direct and Reverse Color *Regular Both Febraban Barcode Enable *Disable...
3.25 Matrix 2 of 5 Enable *Disable Matrix 2 of 5 Check Enable check bit Disable check bit Enable output check bit *Disable output check bit 3.26 Maxicode Enable *Disable...
3.30 Pharmacode Enable Disable 3.31 Micro QR Code Enable *Disable Micro QR Code Direct and Reverse Color *Regular Both 3.32 QR Code *Enable Disable QR Code Direct and Reverse Color *Regular Both...
3.43 ISSN 13 Conversion Setting Convert barcodes starting with 977 to ISSN Enable *Disable ISSN convert to ”-“ Enable *Disable Transmitting the Check Digit of the ISSN Enable *Disable...
4 GS Character Conversion This mode is to output GS control characters as text characters. Enable control character conversion Disable control character conversion 4.1.1 GS Output Mode GS is replaced by | GS is replaced by <GS> GS is replaced by (GS) ’...
5 Code ID Setting Enable output Code ID * Disable output Code ID 5.1.1 Annex: Code ID Table Barcode CodeID Barcode Code ID Airline 2 of 5 HANXIN (Standard 2 of 5/IATA 2 of 5) Aztec Code Interleaved 2 of 5 Codabar Hong Kong 2 of 5(China post) Codablock A...
6 Control Character Output After this function is enabled, control characters (invisible characters) are output as text characters, for example, carriage return is output as <CR>. Enable Disable...
Need help?
Do you have a question about the IG500 and is the answer not in the manual?
Questions and answers