6.2.2Scanner Decoder Firmware Version..16 6.2.3Cradle Decoder Firmware Version ..16 6.2.4Scanner Bluetooth MAC Address..16 6.2.5Cradle Bluetooth MAC Address .... 16 7. Programming Codes ........... 17 Factory Default.......... 17 Bluetooth Setup for IG300BT series ..18 Bluetooth Cradle Setup......20...
1. Introduction Thank you for purchasing this brand-new designed 2D imager hand held barcode scanner. This is a cutting-edge gun-type Area Imaging barcode scanner which is designed specifically for government administration, custom control, shipping industry and etc. That adds on more user friendly functions and has replaceable cable that makes it more easily to be operated by the customers.
13) The damage of wire or pin of power supply. 14) Some Liquid infiltrate into the equipment. 15) The equipment has been exposed to wet environment. 16) The equipment can’t work well. 17) The equipment has any obvious damage, making the device working abnormally.
2. General Description 2.1 Product Description IG300BT is a high performance wireless 2D imager barcode scanner supporting liner, area imager barcode scanning. This device is very easy to configure by this manual, you can set up by scanning all necessary programming...
3.2 Mounting Once you have unpacked all components, you can start installing the device as below steps: IG300BT Scanner 1) The Scanner must be charged for a minimum of 8 hours before the scanner can be placed in full operation for the first time.
Page 10
LED and beeper warning. IG300BT Cradle Connect the supplied communication cable at the bottom side of the scanner and you will hear a “click” when the connection is made. Turn off the host system. Connect the other side of the communication cable to the right connector of your Host system.
Cable installation Connect cable and adaptor to Cradle. The other end of cable will be connected with Host device. Lock the iron panel of Cradle by screwdriver. Skip resistant pad position 3.3 Set up Bluetooth Communication Before the operation, Bluetooth Communication must be set up between the scanner and cradle.
Page 12
3.3.2. Set up Master Mode Communication Please follow the steps to set up the communication between the scanner and cradle. 1) The scanner must scan “Scanner Master Mode” barcode, to set the scanner in Master mode. 2) Scan the Bluetooth MAC address code located on the bottom of the cradle.
Page 13
4) If successful, Blue LED of scanner will slow flash. 5) If the connections failed the scanner indicates with 3 shot beeps. 3.3.4. Sleep Mode The scanner is equipped with sleep mode function to save battery energy when the scanner is not used for 1 minute or 10 minute (setting by scanning the according programming code, please see chapter 7.).
4. Configuring 4.1 Preface How to configure this device: The Barcode Programming Feature gives the possibility to change the scanner settings with use programming codes. 4.2 Changing Scanner Settings with Programming Codes You can setup your device by scanning all necessary programming codes for parameters that meet applications.
4.3 Changing Scanner Settings with Utility Tool Manufacturer has setup this scanner with the most common used programming codes, It could be possible that you need more advanced settings to use the scanner without any problems into your application. In this case you can setup your scanner by using the advanced Utility Tool.
5. Operating Settings 5.1 Scanning Triggering <Level> A reading session begins (lighting and decode processing on) when beam is activated and stops when beam is deactivated. Continuous Scanning When the scanner is turned on a continuous reading session begins (lighting and decode processing on). Note: The continue scanning mode doesn’t support the IG-300BT series.
Page 17
When a barcode is detected, the lighting automatically turns on and stays on until another period of inactivity (timeout). After the timeout the scan engine starts flashing again. Level + Flashing This mode allows you the switch between level and flashing mode.
When in Level trigger mode, after a period of inactivity lasting the time specified by the trigger timeout, the scanner switches back to flashing mode. Toggle This mode allows lighting and decoding toggle when the trigger line is activated. First trigger activation = lighting and decoding on, second trigger activation = lighting and decoding off.
5.3 Good Read Mode When active, the scan engine stops the reading session after a successful decoding. Note: This parameter is NOT used with continuous and continuous + flashing modes. <Active > Not Active 5.4 Buzzer Beep Tone 5.4.1 Beep Tone Setup <High >...
5.4.3 Beep Duration 60 msec <80 msec> 200 msec 6. Imager Settings 6.1 Imager Mode You can set the best reading performance depends on the environment, your used application and type of barcodes. • Linear mode for decode 1D Barcodes. •...
1D and 2D Codes, Bright Environment 1D and 2D Codes With Reflective Surface 6.2 Firmware Version Display the firmware version of the scanner, please scan below barcode. 6.2.1 Engine Firmware Version 6.2.2Scanner Decoder Firmware Version 6.2.3Cradle Decoder Firmware Version 6.2.4Scanner Bluetooth MAC Address 6.2.5Cradle Bluetooth MAC Address ...
7. Programming Codes 7.1 Factory Default 7.1.1 Scanner/Cradle parameters set to factory default Set Scanner /Cradle factory default The scanner and cradle factory default settings are < > shown with bold in the following pages. Reset all configuration parameters to their factory default setting.
7.4.6 Set Pin Code Character (PINCODE max. 6 digits/0-9and A-Z ASCII CODE) Set Default Security Code Barcode (PINCODE = 000000) Begin to Set PINCODE Go to the ASCII Tables in Appendixes; scan 6 labels that represent the PINCODE. Complete to Set PINCODE 7.3 Bluetooth Cradle Setup 7.5.1 Set Cradle Security Mode Set Default Security Code Barcode...
Page 26
2) Go to the ASCII Tables in Appendixes; scan 6 labels that represent the PINCODE. Complete to Set Scanner BT PINCODE 7.5.3 Set Cradle Interface Barcode Set Cradle KB Interface Barcode Set Cradle RS232 Interface Barcode Set Cradle USB HID Interface Barcode 7.5.4 Cradle Baud Rate 1200 2400...
Page 27
38400 7.5.5 Cradle Data Bits 7 data bits <8 data bits> 7.5.6 Cradle Stop bits <1 bit> 2 bits 7.5.7 Cradle Parity <None>...
Page 28
Even Mark Space 7.5.8 Cradle Hand Shaking RTS/CTS Enable <RTS/CTS Disable> ACK/NAK Enable <ACK/NAK Disable> XON/XOFF Enable < XON/XOFF Disable >...
Page 29
7.5.9 Cradle Keyboard Wedge Mode Parameters 1) Terminal type <IBM PC/AT,PS/2> IBM PC/XT IBM PS/2 25, 30 2) Upper/Lower Case <No change> Upper Case Lower Case 3) Send Character by ALT Method Enable <Disable>...
Page 30
Select Numerical Pad <OFF> 5) Time out Between Characters <0 ms> 5 ms 10 ms 25 ms 50ms 100ms 6) Language Selection <US English> UK English...
Page 31
Italian Spanish French German Swedish Switzerland Hungarian Japanese Belgium Portuguese Denmark Netherlands...
Turkey Reserved 1 7.4 Decoding Selection 7.6.1 Symbologies Selection Australian Post ON <Australian Post OFF> AZTEC ON <AZTEC OFF> BPO ON <BPO OFF> Canada Post ON <Canada Post OFF >...
Page 33
CODABAR ON <CODABAR OFF> Codablock A ON <Codablock A OFF > Codablock F ON <Codablock F OFF > CODE 11 ON <CODE 11 OFF> <CODE 39 ON> CODE 39 OFF CODE 93 ON <CODE 93 OFF> <CODE 128 ON>...
Page 34
CODE 128 OFF <GS1-128 ON> GS1-128 OFF <DATAMATRIX ON> DATAMATRIX OFF Dutch Post ON <Dutch Post OFF> <EAN-8 ON> EAN-8 OFF <EAN-13 ON> EAN-13 OFF <EAN 128 ON>...
Page 35
EAN 128 OFF GS1 CC-A/B ON <GS1 CC-A/B OFF> GS1 CC-C ON <GS1 CC-C OFF> GS1 DataBar-Omni ON <GS1 DataBar Omni OFF > GS1 DataBar Limited ON <GS1 DataBar Limited OFF> GS1 DataBar Expanded ON <GS1 DataBar Expanded> Infomail ON...
Page 36
<Infomail OFF> Interleaved 2 of 5 ON <Interleaved 2 of 5 OFF> Japan Post ON <Japan Post OFF> Matrix 2 of 5 ON <Matrix 2 of 5 OFF > MaxiCode ON <MaxiCode OFF> MicroPDF417 ON <MicroPDF417 OFF> MSI ON...
Page 37
<MSI OFF> <PDF417 ON> PDF417 OFF Planet ON <Planet OFF> PLESSEY ON <PLESSEY OFF> Postnet ON <Postnet OFF> QR Code ON <QR Code OFF> Standard 2 of 5 ON...
Page 38
<Standard 2 of 5 OFF> Sweden Post ON <Sweden Post OFF > Telepen ON <Telepen OFF> TLC 39 ON <TLC 39 OFF> <UPC-A ON> UPC-A OFF <UPC-E ON> UPC-E OFF...
7.6.2 Disable All Symbologies. If you want to disable all Symbologies, please scan below programming code. Or you can scan the “Off” option to disable individual symbologies. Disable All Symbologies Note: Do not reset individual parameters settings for each symbology. When you enable a symbology, you will recover the parameter settings stored in memory.
7.17 EAN /UPC Parameters Settings 7.19.1 Reading Type <UPC-A Transmitted As EAN-13> UPC-A Transmitted As UPC-A <UPC-E Transmitted As UPC-E > UPC-E Transmitted As UPC-A EAN-8 Transmitted As EAN 8 > EAN-8 Transmitted As EAN-13 ISBN – Active <ISBN - Not Active> ISMN –...
Page 50
ISSN – Active <ISSN - Not Active > GTIN Processing – Active <GTIN Processing - Not Active > 7.19.2 Supplemental Setup <ADD-ON Digits Not Required but Transmitted If Read> ADD-ON Digits Required and Transmitted ADD-ON 2 ON <ADD-ON 2 OFF > ADD-ON 5 ON <ADD-ON 5 OFF >...
Page 51
7.19.3 Check Digit Transmission <UPC-A Check Digit Transmission ON > UPC-A Check Digit Transmission OFF <UPC-E Check Digit Transmission ON > UPC-E Check Digit Transmission OFF <EAN-8 Check Digit Transmitted ON > EAN-8 Check Digit Transmission OFF <EAN-13 Check Digit Transmitted ON >...
Page 53
Never Linked 7.20.2 Symbology Identifier <UDSI–CC-A/B-Default"G0"> <UDSI–CC-C-Default"G1"> <Code Mark–CC-A/B-Default"*"> <Code Mark–CC-C- Default"*"> 7.20.3 Linear Transmission Only Active <Not Active >...
7.36 Miscellaneous Parameters 7.38.1 Symbology Identifier Symbology Identifier Transmitted <Symbology Identifier Not Transmitted> With this function ON, a leading character will be added to the output string while scanning codes, user may refer to the following table to know what kind of barcode is scanned.
Page 67
<Preamble None > <STX> 7.39.2 Postamble The scanner can be programmed to output Barcode data according to the following format: [BAR CODE DATA] [POSTAMBLE STRING] Example: To send a <ETX> after the Barcode, scan only programming code <ETX>. As a result, the scanner will give the following barcode data output: [BAR CODE DATA] [<ETX>] Postamble None...
Page 72
angle 20°/ Backward: 50°) Vertical 80°±10% (Left 40°/ Right 40°) Interface KBW, RS-232, USB (HID KBW) IG-300BT b) Bluetooth Characteristics (for IG-300BT series) Bluetooth V2.0 Bluetooth Module Standard Frequency Band 2.402GHz ~ 2.480GHz Modulation Method GFSK for 1Mbps RF Output Power Under 4dBm (Class 2) Bluetooth distance Class 2 up to...
Page 73
Scanner Light Signal Status good read and transmitted good read 1 blink and 1 beep and save on Green memory (BT disconnect) battery charged continue on full 3 long blink and 3 memory full long beeps low Battery 4 blink and 4 beeps warning good read 2 blink and 2 beeps...
0.254 3.8 cm 21 cm 0.381 28 cm PDF417 0.16 mm 5.2 cm 14.4 cm 0.254 3.5 cm 22 cm 0.381 3 cm 36 cm F. Test Symbologies Scan one or more of these barcodes to test barcode symbologies you enabled. Codabar Code 39 Code 93...
Page 77
MSI code PDF417 GS1 DataBar Omnidirectional GS1 DataBar Omni Stacked GS1 DataBar Expanded GS1DataBar Expanded Stacked GS1 DataBar Limited UPC A 12345 67890 UPC E 123456...
Page 78
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the installation.
Need help?
Do you have a question about the IG300BT and is the answer not in the manual?
Questions and answers