Maintenance And Inspection Checklist - Bosch Greenstar ZBR 16-3 A Series Installation And Service Instructions For Contractors

Residential gas condensing boiler
Table of Contents

Advertisement

15.2

Maintenance and inspection checklist

▶ Use this form to guide you through the service and maintenance
procedure. Fill out each step according to the findings and work
performed.
Date 
1
Latest fault code from service function 6.A.
2
Fresh water inlet filter (Combi boiler ZWB appliances only).
3
Visual inspection of the combustion air pipes and vent pipes.
4
Dynamic gas pressure
5
Gas-air ratio at min./max. nominal output.
6
Gas and water-side leak test.
7
Inspect electrodes.
8
Inspect heat exchanger block.
9
Check burner.
10
Inspect diaphragm in mixer unit.
11
Clean condensate trap.
12
With the system depressurized, check the expansion
vessel pre-charge pressure vs. the static head of the
heating system.
13
Check the heating system filling pressure.
14
Inspect electrical wiring for damage.
15
Check settings of the heating control.
16
Check set service functions according to commissioning report.
Table 33 Maintenance and inspection checklist
Greenstar – 6721822579 (2020/03)
inches
W.C.
(mbar)
min. %
max. %
psi (bar)
psi (bar)
Inspection and maintenance
71

Advertisement

Table of Contents
loading