Lenovo ThinkSystem SR675 V3 Manual page 156

Hide thumbs Also See for ThinkSystem SR675 V3:
Table of Contents

Advertisement

• FQXSFMA0026G: Multi-bit CE occurred on DIMM [arg1], need to restart the system for DIMM Self-
healing to attempt post package repair (PPR)
Severity: Warning
User Action:
Complete the following steps:
1. Restart the system to allow for DIMM Self-healing to attempt hard post package repair (PPR) and
confirm that event ID FQXSFMA0026I was recorded.
2. If the problem persists or if PPR attempt failed due to event ID FQXSFMA0027M or
FQXSFMA0028M, collect Service Data logs and contact Lenovo Support.
• FQXSFMA0026I: DIMM [arg1] Self-healing, attempt post package repair (PPR) succeeded at Rank
[arg2] Sub Rank [arg3] Bank [arg4] Row [arg5] on Device [arg6]. [arg7]
Severity: Info
User Action:
Complete the following steps:
1. Information only; no action is required.
2. Note: Post Package Repair (PPR) – is the memory Self-Healing process of substituting the access to
a bad cell or address row with a spare row within the DRAM device.
a. Soft Post Package Repair (sPPR) - repairs a row for the current boot cycle. If system power is
removed or the system is rebooted (reset), the DIMM reverts to its original state.
b. Hard Post Package Repair (hPPR) – permanently repairs a row.
• FQXSFMA0027G: Multi-bit CE occurred on DIMM [arg1] different rows.[arg2]
Severity: Warning
User Action:
Complete the following steps:
1. Run advance memory test using the XClarity Provisioning Manager. Click Diagnostics > Run
Diagnostics > Memory Test > Advanced Memory Test to repair the DIMM.
2. Reseat the failing DIMM identified by LightPath and/or event log entry.
3. If the problem persists, collect Service Data logs, and contact Lenovo Support.
• FQXSFMA0027I: Invalid memory configuration (unsupported DIMM Population) recovered.
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0027K: Invalid memory configuration (Unsupported DIMM Population) detected. Please
verify memory configuration is valid.
Severity: Error
User Action:
Complete the following steps:
1. This event could follow an uncorrectable memory error or failed memory test. Check the log and
resolve that event first. DIMMs disabled by other errors or actions could cause this event.
2. Ensure that the DIMMs are populated in the correct sequence, according to the service information
for this product.
152
ThinkSystem SR675 V3 Messages and Codes Reference

Advertisement

Table of Contents
loading

This manual is also suitable for:

7d9q7d9r

Table of Contents