Dimplex Optimyst Cassette 500 Project Operating Instructions Manual page 12

Table of Contents

Advertisement

Product will not operate.
LEDs continuously blink
twice on one side
Product will not operate.
LEDs continuously blink
three times
Product will not operate.
LEDs continuously blink
four times
Product will not operate.
LEDs continuously blink
once every 8 seconds on
one side
Little or No Mist Genera-
tion
The flame effect has too
much smoke.
Bluetooth Receiver stops
working
Remote
Control
stops
working
Low water reading on side that is blinking
Time from max level to min level is too
short.
Conflicting water level readings (min and
max level being read at the same time.)
Fill time from min to max level has been
exceeded
Overflow Detection on side that is blink-
ing
Transducer not operating correctly
Transducer is dirty
Transducer is not sitting correctly in sump
Fan is obstructed or blocked
Nozzle is not on sump correctly
Nozzle is blocked
Flame effect setting is too high
Loose connection
Bluetooth range issue
Bluetooth Receiver connection is loose
Remote control batteries need replacing
Ensure water tank is filling correctly. Check
water supply is working, that there are no
leaks/blockages and absorption valve has not
been activated. Ensure fill cap is positioned
correctly on the sump and secure and fill cap
is secure.
Ensure there are no leaks in the sump.
Ensure that the floats are moving freely within
the sump.
Ensure the product is level.
Ensure water tank is filling correctly. Check
water supply is working, that there are no
leaks/blockages and absorption valve has not
been activated. Ensure fill cap is positioned
correctly on the sump and secure and fill cap
is secure.
Switch off the product and the water supply.
Contact your dealer for assistance.
Check operation of transducer
Clean sump and transducer thoroughly
Switch off product, take nozzle off sump and
ensure transducer is fitted in sump correctly
Remove air filter and clean. Ensure it is placed
back in product correctly.
Ensure Nozzle is sitting on sump correctly
Clean sump, transducer and nozzle thorough-
ly
Turn down the flame effect. Give the product
time to adjust to the new setting
Check connection to the receiver (Fig 9)
Check positioning of Bluetooth Receiver. En-
sure it is not encased in metal or concrete.
Check connection to the receiver (Fig 9)
Replace batteries with two new AAA batteries
12

Advertisement

Table of Contents
loading

Table of Contents