Ventilation system
Hide thumbs Also See for DA 217-2:

Advertisement

Installation
Air extraction exhaust
connection
^ Connect the ductwork to the exhaust
connection using whatever means
are appropriate for the type of
ductwork being installed (hose
clamp, duct tape, etc.)
^ Direct the duct through the back wall
or the ceiling.
^ See "Air extraction" for further details.
36
Recirculation connection
Recirculation mode is used when
venting to the outside of the building is
not possible.
^ Slide the diverter on to the brackets
of plate B.
^ Slip the hose clamps over the flex
hose onto the diverter and the motor
assembly exhaust connection. Once
in place, tighten the hose clamps.
Active charcoal filters must be used
in the recirculation mode.