Advertisement

Quick Links

Operating and Installation
Instructions
Ventilation System
To prevent accidents and damage to the appliance, you must read
these instructions before installing the appliance and using it for the
first time.
en-US
M.-Nr. 12 254 130

Advertisement

Table of Contents
loading

Summary of Contents for Miele PUR 68 W

  • Page 1 Operating and Installation Instructions Ventilation System To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr. 12 254 130...
  • Page 2: Table Of Contents

    Contents IMPORTANT SAFETY INSTRUCTIONS ............Caring for the environment ................12 Description of functions ................... 13 Guide to the ventilation hood ................14 Operation......................16 Turning on the blower..................16 Selecting the power level ..................16 Delayed shut-down ..................... 16 Turning off the blower..................
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user.
  • Page 4  Unauthorized installation, maintenance, and repairs can cause considerable danger for the user. Installation, maintenance, and repairs must only be carried out by a Miele authorized technician.  A damaged ventilation hood can be dangerous. Always check for visible signs of damage. Never use a damaged ventilation hood.
  • Page 5 The function and operation of the protective measures provided in the domestic electrical installation and in this Miele product must also be maintained in isolated operation or in operation that is not synchronized with the grid power supply, or these measures must be replaced by equivalent measures in the installation.
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS  Only open the housing as described in the enclosed “Installation diagram” and in the “Cleaning and care” section of this manual. Under no circumstances should any other parts of the housing be opened. Tampering with electrical connections or components and mechanical parts is highly dangerous to the user and can cause operation faults.
  • Page 7 IMPORTANT SAFETY INSTRUCTIONS  Open flames are a fire hazard. The use of an open flame under the ventilation hood is not permitted. To avoid the danger of fire, do not flambé or grill over an open flame. When switched on, the ventilation hood could draw flames into the filter.
  • Page 8 IMPORTANT SAFETY INSTRUCTIONS  Always turn the ventilation hood on whenever a burner is in use to prevent damage from condensation.  Overheated oil and fat can ignite, causing fire damage to the ventilation hood. Do not leave cookware, pans, and deep-fat fryers unattended when cooking with oil or fat.
  • Page 9 IMPORTANT SAFETY INSTRUCTIONS Proper installation  WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: - a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
  • Page 10  When installing the exhaust duct, only use pipes or tubes made of non-flammable material. These can be obtained from your Miele dealer or from Miele Technical Service. Always observe local building code requirements when selecting duct material.  Exhaust air should not be vented into a chimney or vent flue which is otherwise in use and should not be channeled into ducting which ventilates rooms with fuel-burning installations.
  • Page 11 IMPORTANT SAFETY INSTRUCTIONS Accessories and parts  Use only genuine original Miele parts. If parts or accessories from other manufacturers are used, the warranty may become void.  Defective components should be replaced by Miele original parts only. Only with these parts can safety of the appliance be assured as intended by the manufacturer.
  • Page 12: Caring For The Environment

    Consult with local authorities, dealers or Miele in order to dispose of and recycle electrical and electronic appliances. Miele assumes no responsibility for deleting any personal data left on the appliance being disposed.
  • Page 13: Description Of Functions

    Description of functions The following functions are available on Recirculation mode your ventilation hood, depending on the The recirculation mode requires a model: recirculation kit and OdorFree Charcoal Filter (available as optional accessories, Extraction mode see “Technical Data” for more information) The air is drawn in and cleaned by the grease filters and directed outside.
  • Page 14: Guide To The Ventilation Hood

    Guide to the ventilation hood...
  • Page 15 Guide to the ventilation hood a Telescopic extension piece b Duct cover c Canopy d Controls e Grease filter f Recirculation vents Only for recirculation mode g Overhead lighting h Charcoal filters Optional accessories for recirculation mode i Control for switching the blower on and off j Controls for setting the blower power k Button for switching the lighting on and off...
  • Page 16: Operation

    Operation Turning on the blower Turning off the blower  Press the On/Off control  to turn Switch the blower on as soon as you start cooking. This is to ensure that the blower off. vapors are captured right from the start. The ...
  • Page 17: Turning Power Management On/Off

    Operation Turning power management on/off Safety shut-off You can deactivate power If power management has been management. deactivated, the ventilation hood will Keep in mind that this may increase switch itself off automatically after energy consumption. 12 hours if it has been left on (blower and overhead lighting).
  • Page 18: Energy-Saving Tips

    Energy-saving tips This hood operates in a very efficient and energy-saving manner. The following will help you to save even more energy when using it: - Ensure that there is sufficient ventilation in the kitchen when cooking. If there is insufficient air flow during extraction mode, the hood cannot operate efficiently, causing increased operating noise levels.
  • Page 19: Cleaning And Care

    Unsuitable cleaning agents can treating them with a stainless steel care damage the surfaces and control product (available from Miele). elements. Do not use any cleaning agents Important information for the containing soda, acid, chloride, or controls solvent.
  • Page 20 Ensure the spray arm is not obstructed.  Use a commonly available household dishwashing detergent.  In a Miele dishwasher use the “Normal” program. Depending on the detergent used, cleaning the filters in a dishwasher may cause the inside filter surfaces to become discolored.
  • Page 21: Replacing The Grease Filter

    Charcoal filters are available to order via  Reinstall the grease filters. When the Miele Web Store, Miele Technical inserting the filters, make sure that Service (see end of this manual for the locking clip is facing down.
  • Page 22: Disposing Of Charcoal Filters

    Bulb type ......LED, GU10 Power ..........3W The bulb will then drop downwards. Light bulbs are available from Miele or  Grip the light bulb, turn it specialist dealers. counterclockwise and take it out.  Screw the new bulb into the socket and push it upwards.
  • Page 23: Customer Service

    In the event of a fault which you cannot remedy yourself, please contact your Miele dealer or Miele Customer Service. You can book a Miele Service Call online at www.miele.com/service. Contact information for Miele Customer Service can be found at the end of this document.
  • Page 24: Installation

    *INSTALLATION* Installation Before installation  Before installation, it is important 8 screws measuring 5 x 60 mm and to read the information contained in this chapter and in the “IMPORTANT 8 plugs measuring 8 x 50 mm SAFETY INSTRUCTIONS” chapter. for attaching to the wall  Removing the protective film The screws and plugs are designed for use in solid walls only.
  • Page 25 *INSTALLATION* Installation Conversion kit for recirculation mode The conversion kit contains an exhaust grille, hose, and hose clips (not supplied, but available as an optional accessory. See “Technical data”). 1 lever For removing the bulbs...
  • Page 26: Appliance Dimensions

    *INSTALLATION* Installation Appliance dimensions The drawing is not to scale...
  • Page 27: Distance Between Cooktop And Ventilation Hood (S)

    Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood. Please also observe the information contained in the “IMPORTANT SAFETY INSTRUCTIONS” section. Minimum distance S Cooking appliance Miele Non-Miele appliance appliance Electric Cooktops 24" (610 mm) Electric Barbeques and Fryers 26"...
  • Page 28: Installation Recommendations

    *INSTALLATION* Installation Installation recommendations Drilling diagram for wall mounting - A distance of at least 26" (660 mm) is recommended above electric  When drilling, please follow the cooktops to provide more workspace directions contained on the and easier cooking under the hood. accompanying installation sheet.
  • Page 29: Plywood Backing

    *INSTALLATION* Installation  Make a cutting line 3“ (76 mm) above Plywood backing and 3” (76 mm) below the outline of The majority of the weight of the the retaining plate. installed ventilation system will be  Find the studs  to the left and right supported by the lower retaining of the mounting location by tapping plate.
  • Page 30: Air Venting

    “Appliance dimensions”). This applies If the exhaust is ducted through an in particular when using flat ducting. outside wall, a Miele wall vent or roof - The ducting should be as short and vent (available as an optional straight as possible.
  • Page 31: Condensate

    If the ducting is to run through cool the direction of airflow. rooms or ceiling space, for example, the significant variations in temperature Miele will not accept warranty claims between the different areas can cause for any functional defects or damage condensate to form. Insulate the caused by inadequate ducting.
  • Page 32: Electrical Connection

    CSA C22.1-12, appliance to your power supply, Canadian Electrical Code, Part I. please consult a licensed electrician or call Miele’s Technical Service Department. WARNING: THIS APPLIANCE MUST BE GROUNDED...
  • Page 33: Technical Data

    Technical data Blower motor 350 W Overhead lighting PUR 68 W, PUR 88 W 2 x 3 W PUR 98 W 3 x 3 W Total connected load PUR 68 W, PUR 88 W 356 W PUR 98 W 359 W Supply voltage, frequency 120 V AC, 60 Hz Fuse 15 A Power cord length 4' 11" (1.5 m) Weight PUR 68 W 46.2 lbs (21 kg) PUR 88 W 50.6 lbs (23 kg)
  • Page 35 Customer Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Headquarters and Miele Centre Princeton, NJ 08540 161 Four Valley Drive www.mieleusa.com Vaughan, ON L4K 4V8 www.miele.ca Customer Support Phone: 888-99-MIELE (64353) Customer Care Centre info@mieleusa.com...
  • Page 36 PUR 68 W, PUR 88 W, PUR 98 W en-US M.-Nr. 12 254 130 / 00...