Ventilation system
Hide thumbs Also See for DA 217-2:

Advertisement

Installation
^ Secure the canopy with 5 x 40 mm
screws into each drilled hole.
^ DA 217-2:
Secure the canopy with a 5 x 40 mm
screw.
^ DA 219-2:
Secure the canopy with two
5 x 40 mm screws.
^ Replace the glass light cover.
34
Inserting the non-return flap
^ Air extraction:
If a non-return flap is not present in
the venting system, the non-return
flap supplied must be fitted into the
exhaust connection on the motor. The
flaps must open upwards.
^ The hood is designed for 6" (150 mm)
exhaust ducting. If 5" (125 mm)
exhaust ducting is used the reducing
collar must be fitted into the exhaust
connection on the motor (see "Air
extraction").
^ Recirculation mode:
The non-return flap is not required.