Page 1
Operator's manual Portable Generator P Inverter series P3000i P3500i/O P3500i P7500i...
Page 4
Errors excepted. The machine on the cover may have special equipment (options). Manufacturer PR Industrial s.r.l. Loc. Il Piano 53031 Casole d’Elsa (SI) - Italy Tel.: +39 0577965200 E-mail address: info@pramac.com Original operator's manual...
Page 6
Safety and information labels Standard package Lifting and transporting Operation 7.1 Prepare the machine for first-time application 7.2 Accessories Installation (only for P7500i) 7.3 Power requirements 7.4 Performance loss with high altitude application 7.5 Ground 7.6 Heavy duty operation 7.7 Installation 7.8 Use of extension cables...
Page 7
Basic troubleshooting 10 Disposal 10.1 Disposal of waste electrical and electronic equipment 11 Technical data 11.1 P3000i 11.2 P3500i 11.3 P3500i/o 11.4 P7500i 12 Diagram 12.1 P3000i 12.2 P3500i 12.3 P3500i/o 12.4 P7500i EC declaration of conformity...
Page 8
This operator's manual is not a manual for extensive maintenance or repair work. Such work should be carried out by PRAMAC service or by technically trained personnel. The PRAMAC machine should be operated and maintained in accordance with this operator's manual. An improper operation or improper maintenance can pose dangers.
Page 9
2 Introduction Introduction Means of representation for this operator's manual Warning symbols This operator's manual contains safety information of the categories: DANGER, WARNING, CAUTION, NOTICE. They should be followed to prevent danger to life and limb of the operator or damage to equipment and exclude improper service.
Page 10
Depending on your country, your PRAMAC representative is your PRAMAC service, your PRAMAC affiliate or your PRAMAC dealer. You can find the addresses in the Internet at WWW.PRAMAC.COM The address of the manufacturer is located at the beginning of this operator's manual.
Page 11
3 Safety Regulations Safety Regulations Safety information in this operator's manual This operator's manual contains safety regulations in the categories: DANGER, WARNING, CAUTION, NOTE and COMMENT. These are to be followed in order to reduce the danger of injury, damage to equipment or improper service. This is a safety warning symbol that warns against possible danger of injury.
Page 12
3 Safety Regulations Description and purpose of the machine This machine is a portable power source. The portable generator from PRAMAC consists of a frame, which includes a fuel tank, a gasoline engine, a control panel and an electrical alternator. The control panel contains controls and bushings.
Page 13
3 Safety Regulations Operational safety DANGER Carbon monoxide. The application of a generator in buildings can LEAD TO DEATH WITHIN MINUTES. The exhaust fumes from the generator contain carbon monoxide (CO). This is an invisible odorless poison. If the exhaust fumes of the generator can be smelled, CO is being inhaled.
Page 14
3 Safety Regulations Connection prerequisites The following prerequisites are to be met to connect the generator to the building's mains supply. ▪ The generator must meet the prerequisites with regard to performance, voltage and frequency of the equipment. ▪ The generator must be disconnected from the electric power supply. ▪...
Page 15
3 Safety Regulations ▪ NEVER overload generator. The total amperage of the parts connected to the generator may not exceed the output limit. ▪ NEVER operate the machine in snow, rain or standing water. ▪ NEVER allow untrained personnel to operate or maintain the generator. Familiarize yourself with the operation and shutdown before starting the generator.
Page 16
3 Safety Regulations Safety when using combustion engines WARNING Combustion engines pose a particular danger during operation and when refueling. Failure to follow the warning notices and safety standards can lead to serious injury or death. ➢ Read and always observe the warning notices in the operator's manual of the engine and the safety instructions below.
Page 17
3 Safety Regulations Safety when refueling When refueling the machine: ▪ Immediately wipe away any spilled fuel. ▪ Fill the fuel tank in a well-ventilated area. ▪ Reattach the fuel tank cap after refueling. ▪ Do not smoke. ▪ Do not refuel hot or running engines. ▪...
Page 18
ALWAYS keep fuel lines in a good condition and connected correctly. Leaking fuel and gases are highly explosive. ▪ If spare parts are required for this machine, only use parts from PRAMAC or parts that match the original exactly in terms of dimensions, model, intensity and material.
Page 19
4 Safety and Information labels Safety and information labels There are labels on your equipment that contain important information and safety instructions. ▪ Keep all labels legible. ▪ Replace missing or illegible labels. The item numbers on the labels can be found in the parts book. Item Label Description...
Page 20
5 Standard package Standard package The standard package includes: ▪ Equipment. ▪ Operator's manual. ▪ CE declaration...
Page 21
6 Lifting and transporting Lifting and transporting Lifting the machine This compact generator is heavy enough to cause injury in the event of incorrect hoisting technology. Observe the following instructions to lift the generator: ▪ Do not try to lift the generator without help. Use suitable lifting bars e.g. loops, chains, twisting hooks, ramps or car jacks.
Page 22
Check the machine and its components for damage. Do not operate the machine if you find visible damage! Ask the PRAMAC dealer for advice at once. Check whether all of the parts belonging to the machine have been delivered and whether all loose parts and fasteners are present.
Page 23
7 Operation Accessories Installation (only for P7500i) Remove accessories Remove the attachment, remove the generator and attachment box from the packing box, and count the number of attachment according to the following table. Wheel kit installation Tool requirements: 12 mm wrench, 10 mm wrench, crosshead screwdriver used for battery wiring and clamp.
Page 24
The "General power requirements for starting" information only applies as a general guideline to assist you in determining the power requirements. The nearest PRAMAC dealer, tool manufacturer can help you if you have questions. NOTE: Do not exceed the specified current limit at any plug receptacle.
Page 25
7 Operation Performance loss with high altitude application Generators run differently due to altitude and temperature differences. Unmodified internal combustion engines have reduced performance at high altitudes due to the lower air pressure. This means less performance and therefore a reduced power exploitation.
Page 26
7 Operation Ground CAUTION The mid-point (neutral) conductor of this equipment is not grounded. Do not drive the PE rod into the ground under normal operating conditions. Refer to the local regulations if the equipment is intended to power a building or similar system.
Page 27
7 Operation Use of extension cables A loss of power takes place when connecting electrical equipment or a tool to the generator with an extension cable — the longer the cable, the greater the loss of power. This means that less voltage is conveyed to the electrical equipment and the input current is increased or the performance is reduced.
Page 28
7 Operation Table for extension cable minimum size Extension cable minimum size 230V/1~/50Hz 400V/3~/50Hz Length in m Length in m Ampere - performance variable Cross-section surface in mm Diagram for extension cable minimum size...
Page 29
7 Operation Control Panels P3000i P3500i/O P3500i Oil Warning Light Overload Indicator Light AC Pilot Light Hourmeter / Page display / USB Outlets AC breaker AC Outlets: this socket is only corresponding to a market, the different laws and regulations according to the sales area changes corresponding to the socket.
Page 30
7 Operation Digital display meter DC Outlet USB Outlets DC PROTECTION Parallel outlets (with parallel unit) AC breaker AC breaker AC Outlets: this socket is only corresponding to a market, the different laws and regulations according to the sales area changes corresponding to the socket.
Page 31
7 Operation 7.10 Control Functions Throttle Throttle When the Throttle switch is in the “I” position the throttle controls the engine speed according to the connected electrical load. The results are better fuel consumption and less noise. When the switch is in the “O” position the engine runs at 4,500 rpm regardless of the electrical load.
Page 32
7 Operation After checking, restart the engine. NOTE: The Overload Alarm may come on for a few seconds when first using electrical devices that require a large starting current, such as a compressor, pump, or refrigerator. This is normal behavior it is not a malfunction. Low Oil Alarm (Red) When the engine oil falls below the required level the Low Oil Alarm will come on and the engine will stop automatically.
Page 33
7 Operation Off / Run / Choke switch The Off / Run / Choke switch controls the flow of gasoline from the fuel tank to the carburetor. The switch should be in the “I” position when starting and operating the generator. The switch should be in the “O” position when the engine is not running and when storing or transporting the unit.
Page 34
NOTE: Do not disconnect any parallel kit connections once the units are running Start both units per starting instructions. Once the green output indicator illuminates, devices can be connected and turned on using the parallel kit outlet. Follow Stopping the engine instructions NOTE: Only use Pramac approved parallel kit...
Page 35
7 Operation 7.11 Before starting DANGER Carbon monoxide. The application of a generator in buildings can LEAD TO DEATH WITHIN MINUTES. The exhaust fumes from the generator contain carbon monoxide (CO). This is an invisible odorless poison. If the exhaust fumes of the generator can be smelled, CO is being inhaled.
Page 36
Using the funnel (provided) fill with 0.4 L of SAE 10W-30 or 10W-40 (provided) (see figure 3). See figure 4 for proper oil level. (Figure 4: left image for P3000i-P3500i-P3500Io, right image for P7500i) Replace oil filler cap and secure side panel with screws.
Page 37
7 Operation 7.12 Starting the engine OPERATE THE ENGINE IN A WELL VENTILATED AREA. DO NOT connect any electrical devices to the outlets on the generator before starting the engine. 17.12.1 P3000i-P3500i-P3500i/O 1. Turn the Economy Throttle switch "O" You may turn the Economy Throttle switch to "I" once the engine is started and a steady idle is achieved, (below 0°(32°F)/5mins, below 5°C(41 °F)/3mins.).
Page 38
7 Operation 17.12.2 P7500i 1. According to the required voltage requirements, select the gear of voltage change-over switch. 2. Turn the switch to “On” position. Press and release the start switch button. The start switch will start the motor for 5 seconds. When the engine starts successfully, the starter will stop automatically.
Page 39
7 Operation Turn the Off / Run / Choke switch to “O”.
Page 40
8 Maintenance Maintenance Period maintenance schedule The following table contains the basic maintenance jobs for the machine. Jobs selected with a check mark can be performed by the operator. The jobs marked with a small box require special training and special equipment. Daily After the Every 3...
Page 41
Add engine oil to the upper level as seen in the figure 1. (Figure 1: left image for P3000i-P3500i-P3500Io, right image for P7500i) Recommended engine oil: YAMALUBE4 (10W-40), SAE 10W-30 or 10W-40, SAE#30, SAE#20, SAE#10W.
Page 42
Remove the screw and then remove the cover. Remove the bolt and then remove the air filter case cover. (Left image for P3000i-P3500i-P3500Io, right image for P7500i) Remove the foam element. Wash the foam element in solvent and dry it.
Page 43
8 Maintenance Remove the muffler cap, the muffler screen and spark arrester.
Page 44
8 Maintenance (Left image for P3000i-P3500i-P3500Io, right image for P7500i) Remove the carbon deposits on the muffler screen and spark arrester using a wire brush. Use wire brush lightly to avoid damaging the muffler screen or spark arrestor. (Left image for P3000i-P3500i-P3500Io, right image for P7500i) Check the muffler screen and spark arrester replace them if damaged.
Page 45
8 Maintenance WARNING GASOLINE IS FLAMMABLE. DO NOT perform this maintenance while smoking or near an open flame. Spark plug See image below. Clean or replace the spark plug as needed. See engine manual. WARNING The exhaust will become very hot during operation and also remains hot for a while after the engine is switched off.
Page 46
8 Maintenance d. Remove the battery band from the hook at the bottom of generator. e. Remove the battery from the mounting box. Install the battery (where available) Battery terminals, wiring terminal and associated accessories containing lead and lead compounds. Wash hands immediately after handling. 1.
Page 47
8 Maintenance • Be sure to connect the red battery charger lead to the positive (+) battery terminal, and connect the black lead to the negative (-) battery terminal. Do not reverse these options. • Connect the battery charger leads to the battery terminals securely so that they are not disconnected due to engine vibration or other disturbances.
Page 48
8 Maintenance Drain the fuel from the carburetor by loosening the drain screw on the carburetor float chamber. Turn the Off / Run / Choke switch to "O" Tighten the drain screw. Install the cover and tighten the screws. Turn the fuel tank cap air vent knob to "OFF" (where available) Store the generator in a dry, well-ventilated place, with the cover placed over it.
Page 49
9 Basic troubleshooting Basic troubleshooting Problem / symptom Cause / remedy ▪ Engine switch is in the "Start" position. Check the following if the ▪ Fuel cock is open. engine does not start: ▪ Fuel is replenished. ▪ Choke lever is in the correct position. The choke should be closed when starting a cold engine.
Page 50
10 Disposal Disposal 10.1 Disposal of waste electrical and electronic equipment Professional disposal of this machine avoids negative effects on human health and the environment, helps with the targeted treatment of pollutants and makes it possible to recycle valuable raw materials. For customers in EU countries This machine is not affected by the European directive for old electrical and electronic equipment (Waste Electrical and Electronic Equipment (WEEE)).
Page 51
11 Technical data Technical data 11.1 P3000i P3000i Designation Unit MAX Power 2.52 Cont. Operating Power Length Width Height Weight Engine Combustion method Four-stroke Cooling Air cooling Cylinders Displacement Fuel type Gasoline Fuel consumption@75% Mixture preparation Carburetor Tank capacity Max. oil filling Spark plug type E6RTC or equivalent Spark plug air gap...
Page 52
11 Technical data 11.2 P3500i P3500i Designation Unit MAX Power Cont. Operating Power Length Width Height Weight 49.5 Engine Combustion method Four-stroke Cooling Air cooling Cylinders Displacement Fuel type Gasoline Fuel consumption@75% Mixture preparation Carburetor Tank capacity Max. oil filling Spark plug type F7RTC / BPR6ES or equivalent Spark plug air gap...
Page 53
11 Technical data 11.3 P3500i/o Designation Unit P3500i/o MAX Power Cont. Operating Power Length Width Height Weight Engine Combustion method Four-stroke Cooling Air cooling Cylinders Displacement 212cc Fuel type Gasoline Fuel consumption@75% Mixture preparation Carburetor Tank capacity Max. oil filling Spark plug type F7RTC / BPR6ES or equivalent Spark plug air gap...
Page 54
11 Technical data 11.4 P7500i Designation Unit P7500i MAX Power Cont. Operating Power Length Width Height Weight Engine Combustion method Four-stroke Cooling Air cooling Cylinders Displacement 420cc Fuel type Gasoline Fuel consumption@75% 2.25 Mixture preparation Carburetor Tank capacity Max. oil filling 1.45...
Page 59
12 Diagram Here below a fac-simile of CE declaration. Original Ce declaration is provided with the rest of documents as for point 5. Fac-simile of CE Declaration of conformity...
Need help?
Do you have a question about the P7500i and is the answer not in the manual?
Questions and answers