To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Door Handle Removal
Condition Requirements:
Door Lowered
1. Remove two plugs from each side of door assembly.
2. Remove three screws from each door handle end
cap.
3. Pull end cap up then out to remove from handle.
4. Reverse procedure for installation.
Outer Door Panel Assembly Removal
Condition Requirements:
Door Assembly Removed
1. Place the door handle side down on a protected
surface.
2. Remove seven screws that attach the outer door
panel assembly to the inner door panel assembly.
©2008 Viking Preferred Service
3. Lift the inner door panel assembly from the outer
door panel assembly.
4. Reverse procedure for installation.
Outer Door Glass Removal
Condition Requirements:
Outer Door Panel Assembly Removed
Door Handle Removed
1. Remove four locknuts and door insulation bracket
from door insulation panel.
2. Remove door insulation panel by sliding torward the
bottom of the door skin.
3. Remove door skin insulation from door skin.
Disassembly
25