Installation manual Cassette 4 ways compact CONTENTS PAGE Use the attached accessories parts and specified parts for installation. otherwise, it will cause the set to fall, water leakage, electrical PRECAUTIONS..................1 shock fire. INSTALLATION INFORMATION..............2 INSPECTING AND HANDLING THE UNIT..........2 Install at a strong and firm location which is able to withstand the set' s weight.
Installation manual Cassette 4 ways compact Carry out the specified installation work after taking into 2. INSTALLATION INFORMATION 2. INSTALLATION INFORMATION account strong winds, typhoons or earthquakes. Improper installation work may result in the equipment falling and causing accidents. To install properly, please read this "installation manual" at If the refrigerant leaks during installation, ventilate the first.
Installation manual Cassette 4 ways compact 4. ATTACHED FITTINGS Please check whether the following fittings are of full scope. If there are some spare fittings, please restore them carefully. Four-way Four-way NAME SHAPE Cassette Cassette (compact) 1. Installation paper board INSTALLATION FITTINGS 2.
Installation manual Cassette 4 ways compact 5. INDOOR UNIT INSTALLATION Please adjust the hexangular nuts on the four installation hooks evenly, to ensure the balance of the body. 5.1 Installation place If the drainpipe is awry, leakage will be caused by the malfunction of the water-level switch.
Page 6
Installation manual Cassette 4 ways compact 60 (Electronic Exp. Valve Box EXV) Drain side (*Refer to IMPORTANT NOTE) IMPORTANT NOTE The valve expansion box (EXV) must always be connected using the supplied accessories. The box can be placed next to the body of the unit (as manufactured) or a distance of 3 m. Liquid Connection Connective Pipe EXV Box...
Installation manual Cassette 4 ways compact 6. INSTALL THE CONNECTING PIPE Install the panel on the main body with bolt (M5×16) and washer. (Refer to Fig.5-11 ) Adjust the four panel hook screws to keep the panel Check whether the height drop between the indoor unit and horizontal, and screw them up to the ceiling evenly.
Installation manual Cassette 4 ways compact 7.2 Check The Leakage The necessary filling amount of refrigerant ● Check all the joints with the leak detector or soap water. (See Refrigerant volume to be added is calculated according to Fig.7-6 as a reference illustration) outdoor unit installation manual .Be sure to add refrigerant measuring by a scale.
Installation manual Cassette 4 ways compact 8.2 Drainage Test 5) When connecting drainpipe, don’t drag the pipe that would pull the main unit. For this, please arrange bearing points every 0.8 to 1.0 meter to avoid pipe be bended (See Fig.8-1 b). Check whether the drainpipe is unhindered 6) When connect a lengthen drainpipe, apply protective tube to New built house should have this test done before paving...
Installation manual Cassette 4 ways compact Table.9-1 Terminal board diagram Please refer to the indoor unit wiring diagram for the wiring. Model(W) 1500~5600 Phase 1-Phase Power NOTE Frequency and volt 220-240~50Hz The air-conditioners can connect with Central Control Circuit breaker/fuse (A) 15/15 Monitor (CCM).
Page 12
(b y default) must activate the Auto-address dip-switch (except 3 pipes system). 01 means temp. compensation Note: To make the addressing you can contact with Mundoclima after sales service. value is 2 under heat mode Switch setting 10 means temp. compensation...
Installation manual Cassette 4 ways compact 12. TEST OPERATION 11. TROUBLE SHOOTING The test operation must be carried out after the entire installation Table.11-1 has been completed. Error code Indication Please confirm the following points before the test operation: Timer LED and run LED No address when first time flash together,or show ●...