mundoclima MINI MVD V6M Installation And Owner's Manual And Information Requirements

mundoclima MINI MVD V6M Installation And Owner's Manual And Information Requirements

Outdoor unit

Advertisement

Quick Links

MVD
MINI MVD V6M OUTDOOR UNIT
Installation and owner's manual
and information requirements
MVD-V280W/DGN1
MVD-V335W/DGN1
CL23274 to CL23275
English
www.mundoclima.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MINI MVD V6M and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for mundoclima MINI MVD V6M

  • Page 1 MINI MVD V6M OUTDOOR UNIT Installation and owner's manual and information requirements MVD-V280W/DGN1 MVD-V335W/DGN1 CL23274 to CL23275 English www.mundoclima.com...
  • Page 2 Mini MVD V6M Installation and owner's manual CONTENTS Installation manual ..................3 Owner's manual ..................16 EU 2016/2281 Information requirements (for units > 12kW) CONTENTS Information requirements ...............24 /DWKZd Ed Thank you for selectiong super quality Air Conditiones. To ensure satisfactory operation for many ears to come, this manual should be read carefully before the installation and before using the air conditioner.
  • Page 3: Table Of Contents

    Mini MVD V6M Installation manual CONTENTS PAGE CAUTION Do not connect the Appliance from Main Power Supply directly. PRECAUTIONS..................3 ATTACHED FITTINGS................4 OUTDOOR UNIT INSTALLATION..............5 INSTALL THE CONNECTING PIPE............6 WARNING ELECTRICAL WIRING................11 TEST RUNNING..................14 Ask an authorized dealer or qualified installation professional to CONFIGURATION...................14...
  • Page 4: Attached Fittings

    Mini MVD V6M Installation manual 3) Spanner The temperature of refrigerant circuit will be high, please keep the 4) Pipe cutter interconnection cable away from the copper tube. 5) Knife The power cord type designation is H05RN-For above/H07RN-F. 6) Reamer...
  • Page 5: Outdoor Unit Installation

    Mini MVD V6M Installation manual When installing the outdoor unit in a place that is constantly CAUTION exposed to a strong wind such as the upper stairs or rooftop of a building, apply the windproof measures referring to the following Keep indoor unit, outdoor unit, power supply wiring and examples.
  • Page 6: Install The Connecting Pipe

    Mini MVD V6M Installation manual 4. INSTALL THE CONNECTING PIPE 3.3 Moving and installation Since the gravity center of the unit is not at its physical center, Check whether the height drop between the indoor unit and so please be careful when lifting it with a sling.
  • Page 7 Mini MVD V6M Installation manual The second connect methond Check point of indoor unit Outdoor Unit(Take Model 280 for example) Check point of outdoor unit intdoor Units Fig. 4-2 4.3 Heat Insulation The first Line Branch Pipe Do the heat insulation to the pipes of air side and liquid side separately.
  • Page 8 Mini MVD V6M Installation manual Table 4-8 Branch header must be connected with indoor units directly, the further branch connection is not allowed. Capacity of Maximum Sum Capacity Outdoor Unit Outdoor unit Quantity of of Indoor unit (kW) (horsepower) Indoor unit...
  • Page 9 Mini MVD V6M Installation manual The indoor unit below to the main pipe L3 are N3 N6, and its to- Indoor unit branch pipe WDO FDSDFLW\ LV î  WKH VL]H RI SLSH / LV   Inner branch pipes are a~f, the size selection please refers to and the branch pipe C should be FQZHN-01D.
  • Page 10 Mini MVD V6M Installation manual The second cennect methond Outdoor unit Pipe Length(from the nearest branch pipe equivalent length Maximum pipe equivalent length (from the first line branch pipe) Maximum pipe equivalent length The first line Branch Pipe Indoor unit Fig.4-8...
  • Page 11: Electrical Wiring

    Mini MVD V6M Installation manual 5. ELECTRICAL WIRING CAUTION Design a dedicated power supply for the indoor unit and outdoor unit. If the power supply uses a branch loop, install an electricity leakage protector and a manual switch. The power supply, electric leakage protectors, and manual switches of the indoor units that connect to the same outdoor unit must be universal.
  • Page 12 Mini MVD V6M Installation manual Outdoor unit P Q E Note: The parts in the dotted line box are optional.Contact the local distributor to purchase them if required. Use a shield cable and ground the shielding layer. Indoor unit Indoor unit...
  • Page 13 Mini MVD V6M Installation manual Wrong connection may cause malfunction . NOTE Wiring Connection The wire diameter and continuous length is under the Seal the wiring connection with the insulation material , or the condition that the voltage vibration is within 2%. If the condensing dew will be caused.
  • Page 14: Test Running

    Mini MVD V6M Installation manual 6. TEST RUNNING Operate according to "gist for test running" on the electric control box NOTE cover. Please cut off the power supply when changing the dial switch CAUTION Test running can not start until the outdoor unit has been connected to the power for 12hr.
  • Page 15: Error Codes

    Mini MVD V6M Installation manual 8.1 Important information for the used refrigerant This product has the fluorinated gas, it is forbidden to release to air. Refrigerant type: R410A; Volume of GWP: 2088; 2) For equipment that contains fluorinated greenhouse gases in...
  • Page 16: Important Safety Information

    Owner's manual Mini MVD V6M Do not insert fingers, rods or other objects into the air OWNER'S MANUAL inlet or outlet. When the fan is rotating at high speed, it will cause injury. CONTENTS PAGE Never use a flammable spray such as hair spray, lacqueror paint near the unit.
  • Page 17: Operation Range

    Owner's manual Mini MVD V6M The temperature of refrigerant circuit will be high, please Do not operate the air conditioner with a wet hand. keep the interconnection cable away from the copper tube. An electric shock may happen. 5.Poor environmental conditions, the appliance should be Do not touch the heat exchanger fins.
  • Page 18 Owner's manual Mini MVD V6M 3.5 Cooling and heating operation NOTE The indoor unit of the intelligent inverter centralized air When the protection equipment starts, please shut down the conditioner can be controlled solely, but the indoor unit in the manual power switch, and restart operation after problem is same system can not run cooling and heating at the same time.
  • Page 19: Malfunction Code Of Outdoor Unit

    Owner's manual Mini MVD V6M MALFUNCTION CODE OF OUTDOOR UNIT Table 4-1 Failure or Protection Type Fault Code Recovery Mode Communication error between main board and Recoverable compressor drive board DC bus voltage error Recoverable Inverter-module protection Recoverable Irrecoverable 3 times of P2 protection in 30 minutes Qty.
  • Page 20: Following Symptoms Are Not Air Conditioner Troubles

    Owner's manual Mini MVD V6M 5. FOLLOWING SYMPTOMS ARE NOT AIR Symptom 4.2: Indoor unit, outdoor unit CONDITIONER TROUBLES A continuous low hissing sound is heard when the system is in operation. Symptom 1: The system does not operate This is the sound of refrigerant gas flowing through both indoor and outdoor units.
  • Page 21 Owner's manual Mini MVD V6M Table 6-1 Symptoms Causes Solution Power failure. Wait for the comeback of power. Power switch is off. Switch on the power. Fuse of power switch may have burned. ReplLocation: Unit does not start Unit does not start...
  • Page 22: Maintenance And Pepair

    Owner's manual Mini MVD V6M 6.2 Troubles and causes of remote controller Before asking for serving or repairing , check the following points. (see in Table 6-2) Table 6-2 Symptoms Causes Solution Check whether the MODE When the automatic mode is...
  • Page 23 Owner's manual Mini MVD V6M 7.1 Maintenance after Unit has been Shut Down 7.4.2 Recommended maintenance and inspection for a Long Period As the use of the unit for many years will eventually lead to a dust For example, in early summer or winter.
  • Page 24 Information requirements Mini MVD V6M INFORMATION REQUIREMENTS (FOR UNITS > 12KW) Cooling - Information requirements for air-to-air air conditioners Information requirements for air-to-air conditioners Model(s): MVD-V335W/DGN1 Test matching indoor units from1, non-duct: 6×MVD-56Q4* Outdoor side heat exchanger of air conditioner:air...
  • Page 25 Information requirements Mini MVD V6M Heating - Information requirements for heat pumps Information requirements for air-to-air conditioners Model(s): MVD-V335W/DGN1 Test matching indoor units from1, non-duct: 6×MVD-56Q4* Outdoor side heat exchanger of air conditioner:air Indoor side heat exchanger of air conditioner:air...
  • Page 26 Information requirements Mini MVD V6M Cooling - Information requirements for air-to-air air conditioners Information requirements for air-to-air conditioners Model(s): MVD-V280W/DGN1 Test matching indoor units from1, non-duct: 4×MVD-71Q4* Outdoor side heat exchanger of air conditioner:air Indoor side heat exchanger of air conditioner:air...
  • Page 27 Information requirements Mini MVD V6M Heating - Information requirements for heat pumps Information requirements for air-to-air conditioners Model(s): MVD-V280W/DGN1 Test matching indoor units from1, non-duct: 4×MVD-71Q4* Outdoor side heat exchanger of air conditioner:air Indoor side heat exchanger of air conditioner:air...
  • Page 28 C/ NÁPOLES 249 P1 08013 BARCELONA SPAIN (+34) 93 446 27 80 www.mundoclima.com...

This manual is also suitable for:

Mvd-v280w/dgn1Mvd-v335w/dgn1

Table of Contents