Troubleshooting

Symptom
Cause of Failure
1.
The PAN08 not working
The PAN08 is not
and LED off
connect to the Main
power
2.
The PAN08 break
down
The shutter move direction
Wrong connection of NC
is reverse
and NO to the motor
PAN08 LED light work fine
1. No association setting
But can not control
2. Same frequency
interference
3. S1 or S2 are pressed in
Two Push Button switch
type, PAN08 would not
accept RF command.
Installation and operation
Recommendation
1. Check power connections
2. Don't open up the PAN08 and send it
for repair.
Swap the NC NO connection
1. Carry out association
2. Wait for a while to re-try
3. Release S1 and S2
1. Put the in wall PAN08 into a wall box and connect the AC power wire L, N to
PAN08 connector L, N.
2. Connect the wall switch to the PAN08 as Fig1.
3. To manually switch up and down of the shutter, simply press the external switch S1
or S2. The detail is described in 7-5.
4. PAN08 built in meter function and can read the Watt, KWh, V(Voltage), I(Current),
PF(Power Factor) of the load by using Z-Wave command class, user can set a
threshold current to get the warning caused by abnormal operation.
5. PAN08 have overload protection function, and can help to prevent short circuit
caused by load.
Fig 1. Assembling and wiring