7-3. Test Run

(1) Turn the indoor unit selector switch to the "ON"
position. (Fig. 5)
(2) With the remote controller, start heating or cooling
operation.
(3) Turn the selector switch to "TEST RUN." (The
indicator lamp blinks during test run operation.)
(4) After the test run is completed, turn the selector
switch to "ON." Operation stops, and remote
controller control becomes possible.
If the OPERATION lamp only blinks or the outdoor
unit does not start approximately 5 minutes after the
start of the test run, perform self-diagnosis by
switching to OFF. Follow the self-diagnosis
procedure listed on the right inside of the grille.
The combination of the 3 indicator lamps indicates
the condition of the system. (Fig. 6)
25
Fig. 5
Fig. 6