6. Turn the coupling nut clockwise until it is fully tightened.
The regulator will seal on the back-check
feature in the LP tank valve, resulting in some
resistance. An additional one-half to three-quarters
turn is required to complete the connection. Tighten
by hand only - do not use tools.
NOTE:
• If you cannot complete the connection, disconnect the
regulator and repeat steps 5 and 6. If you are still unable
to complete the connection, do not use this regulator!
• Call for replacement parts at 1-888-287-0735.
DANGER
• Do not insert any tools or foreign objects into the valve
outlet or safety relief valve. You may damage the
valve and cause a leak. Leaking propane may result in
an explosion, fire, severe personal injury, or death.
WARNING
• Outdoor gas appliance is not intended to be installed
in or on a boat.
• Outdoor gas appliance is not intended to be installed
in or on an RV.
• Never attempt to attach this grill to a self-contained
LP gas system of a camper trailer or motor home.
• Do not use the grill until a leak test is performed.
• If a leak is detected at any time, STOP and call the
fire department.
• If you cannot stop a gas leak, immediately close the
LP tank valve and call a LP gas supplier or your fire
department!
Hold the coupling nut and
regulator as shown for proper
connection to LP tank valve.
Leak Testing Valves, Hose and Regulator
1.
Turn all grill control knobs to OFF.
2. Be sure regulator is tightly connected to the LP tank.
3. Completely open the LP tank valve by turning the OPD
hand wheel counterclockwise. If you hear a rushing sound,
turn the gas off immediately. There is a major leak at the
connection. Correct before proceeding. Call for
replacement parts at 1-888-287-0735.
4. Brush soapy solution onto areas where bubbles are.
5. If "growing" bubbles appear, there is a leak. Close the LP
tank valve immediately and retighten connections. If leaks
cannot be stopped do not try to repair. Call for
replacement parts at 1-888-287-0735.
6. Always close the LP tank valve after performing the leak
test by turning hand wheel clockwise.
7