Rectifying faults
Dynamic power adjustment
6.2
Dynamic power adjustment
This requires use of the appropriate mains fuse.
Observe mains fuse specification!
This function enables aligning the machine to the mains connection fusing to avoid continuous tripping of
the mains fuse. The maximum power input of the machine is limited by an exemplary value for the exis-
ting mains fuse (several levels available).
You can predefine this value in the machine configuration menu > see 5.6 chapter using parameter
The function automatically adjusts the welding power to an uncritical level for the mains fuse.
6.3
Resetting welding parameters to the factory settings
All customised welding parameters that are stored will be replaced by the factory settings.
RESET
Display
6.4
Display machine control software version
The query of the software versions only serves to inform the authorised service staff. It is available in the
machine configuration menu > see 5.6 chapter.
50
0
l
Setting/selection
Input confirmation
User entries are applied, release button(s).
+
+
Figure 6-1
.
099-00T402-EW501
02.07.2020
Need help?
Do you have a question about the T4.02 and is the answer not in the manual?