Fluid Heating Reservoir Removal - Nordson NH-4 Customer Product Manual

Hide thumbs Also See for NH-4:
Table of Contents

Advertisement

Figure 9 Heater Reservoir Replacement
1. O-ring
2. Fluid passage body
3. O-ring
© 2023 Nordson Corporation

Fluid Heating Reservoir Removal

1. Remove the thermostat. Refer to Thermostat Removal procedure.
2. Remove the heat limiter. Refer to Heat Limiter Removal procedure.
3. Remove the heater cartridge. Refer to Heater Cartridge Removal procedure.
4. See Figure 9. Disconnect the fluid inlet (8) and fluid outlet fittings (4). Remove the
O-rings (3, 7) from the fittings and discard them.
5. See Figure 8. Loosen the set screws (1) securing the fluid heating reservoir to the
electrical enclosure. Screws are visible when the enclosure cover is removed.
6. Rotate the fluid heating reservoir assembly counterclockwise to remove it from the
electrical enclosure.
9
4. Outlet fitting
5. O-ring
6. Retaining ring
NH-4 Heaters
1
2
3
4
5
6
7
8
7. O-ring
8. Inlet fitting
9. High-pressure housing
21
1602369-05

Advertisement

Table of Contents
loading