Thermometer Installation - Nordson NH-4 Customer Product Manual

Hide thumbs Also See for NH-4:
Table of Contents

Advertisement

12 NH-4 Heaters

Thermometer Installation

Figure 7 Thermometer Installation
1. Thermometer
2. Standard and stainless steel
thermometer adapter
1602369-05
Install the thermometer at the heater outlet port, or at the filter outlet port. The installation
kit furnished with the heater includes the fittings necessary for either installation.
See Figure 7.
1. Install the close nipple (6) in the heater output port. or hex nipple (6) to the filter output
port.

CAUTION:
Use the stainless steel thermometer and fittings with the stainless steel
NH-4 heater to prevent damage to the equipment.
NOTE:

If the thermometer is installed after the filter, use the hex nipple included with the
heater installation to install the adapter to the filter.
2. Install the applicable thermometer adapter (2 or 5) to the nipple.
3. Install the thermometer (1) to the thermometer adapter.
4. Install the elbow (3) to the thermometer adapter.
5. Connect the high-pressure fluid line to the thermometer adapter elbow.
6. Make sure all fittings are tightened securely.
3. Elbow
4. To filter inlet port
1
2
6
4
Twin Passage Obsolete
1
5
6
4
5. Twin passage thermometer adapter
6. Nipple
3
3
© 2023 Nordson Corporation