Installation & Maintenance
Pre-Installation Considerations
Location
The unit may be closed in on the top, rear and both
sides, but the front must be unobstructed for air circula-
tion and proper operation. Installation should be as
such that the cabinet can be moved forward for servic-
ing, if necessary.
The installation site should be well ventilated with the
temperature above 55°F (13°C) and below 110°F
(43°C). The best results are obtained between 70°F
(21°C) and 90°F (32°C).
The unit must be installed in an area protected from the
elements, such as wind, rain, water spray or drip.
Provision for electricity, water and drain should be
determined.
Electrical Connection
The unit will require an electrical branch circuit of:
115 Volts
60 Hertz
1 Phase
15 Amp delayed action fuse or circuit breaker.
It is recommended that the ice maker is the only appli-
ance plugged into the receptacle. Do not use an exten-
sion cord. Do not use a receptacle that is controlled by
a wall switch.
(See Figure 2-1)
ELECTRICAL GROUND IS REQUIRED ON THIS
APPLIANCE. DO NOT, UNDER ANY CIRCUM-
STANCE, REMOVE THE POWER SUPPLY GROUND
PLUG.
#3752200 - Revision B - May, 2006
Model 506 (UC Ice Maker)
Model 506 (UC Ice Maker)

ELECTRIC SHOCK HAZARD

IMPROPER CONNECTION OF THE EQUIPMENT
GROUNDING CONDUCTOR CAN RESULT IN A
RISK OF ELECTRICAL SHOCK.
DO NOT USE A TWO PRONG ADAPTER.
DO NOT USE AN EXTENSION CORD.
DO NOT HAVE A FUSE IN THE NEUTRAL OR
GROUNDING CIRCUIT.
DO NOT CONNECT TO ELECTRICAL SUPPLY
UNTIL APPLIANCE IS PERMANENTLY GROUND-
ED.
FAILURE TO FOLLOW THESE INSTRUCTIONS
CAN RESULT IN FIRE, ELECTRICAL SHOCK OR
DEATH.
Figure 2-1. Power Cord & Wall Outlet
2-2
3-Prong
Grounding Type
Wall Receptacle
3-Prong
Grounding Plug
Power Supply
Cord