Installation Information; Pre-Installation Considerations; Overall Dimensions; All Models - Sub-Zero UC-15I Service Manual

Undercounter ice machine
Hide thumbs Also See for UC-15I:
Table of Contents

Advertisement

Installation Information

PRE-INSTALLATION CONSIDERATIONS

To properly make and store ice, the model UC-15I:
• Must have an open site (gravity) drain available
(applies to models without a drain pump only). Refer
to specifications found later in this section.
• Must have a grounded, polarized electrical power
supply on a separate circuit servicing only this appli-
ance. If GFCI (ground fault circuit interrupter) is
required by local electrical code or is part of an out-
door installation, it must be breaker type, not outlet
type. Refer to specifications found later in this sec-
tion.
• Must have a cold water supply line available at ice
machine. Refer to specifications found later in this
section.
• Specifications for clearance and air temperature
requirements must be met. Refer to specifications
found later in this section.
• Must be re movable for yearly cleaning procedure.
Refer to specifications found later in this section.

OVERALL DIMENSIONS

33-5/8"
29-5/8"
(854 mm)
(752 mm)
4"
(102 mm)
14-3/4"
(375 mm)
FRONT VIEW
*Does not include door panel
Dimensions in parentheses are in millimeters unless otherwise specified.
#7012423 - Revision B - May, 2011
Model UC-15I (Undercounter Ice Machine)
1-11/16"* (43 mm)
21-5/16"
(541 mm)
33-5/8"
(854 mm)
18"
(457 mm)
21-5/16"
(541 mm)
SIDE VIEW
PROPER INSTALLATION REQUIRES CONNECTION
TO A WATER SUPPLY, A DRAIN AND A DEDICATED
ELECTRICAL CIRCUIT.
ARE
THE
RESPONSIBILITIES
OWNER/OPERATOR. IMPROPER CONNECTIONS
CAN RESULT IN PERSONAL INJURY, SUBSTAN-
TIAL
PROPERTY
MACHINE OPERATION. IF UNABLE TO SAFELY
CONNECT THE ICE MACHINE, CONSULT QUALI-
FIED PROFESSIONALS OR CONTACT SUB-ZERO.
NOTE:
Failure to follow installation guide lines may
affect warranty coverage.
14-3/4"
(375 mm)

ALL MODELS

Overall Width
Overall Height (levelers in)
Overall Depth
Minimum Door Clearance
Rough Opening Width
Rough Opening Height
Minimum Height Required
(levelers in)
115˚
DOOR SWING
Rough Opening Depth
Dimensions may vary ± 1/8" (3 mm).
TOP VIEW
6-1/2"
(165 mm)
2-2
THESE CONNECTIONS
OF
DAMAGE
AND
ERRATIC
14-3/4" (375 mm)
33-5/8" (854 mm)
23" (584 mm)
18" (457 mm)
15-1/4" (387 mm)
34-1/2" (876 mm)
33-5/8" (854 mm)
24" (610mm)
THE

Advertisement

Table of Contents
loading

Table of Contents