Rheem RQRM 15 Series Installation Instructions Manual page 19

Package heat pumps featuring industry standard r-410a refrigerant
Table of Contents

Advertisement

GENERAL DATA - RQPM
NOMINAL SIZES 2-5 TONS [7-17.6 kW]
Model RQPM- Series
Cooling Performance
1
Gross Cooling Capacity Btu [kW]
EER, SEER
2
Nominal CFM/AHRI Rated CFM [L/s]
AHRI Net Cooling Capacity Btu [kW]
Net Sensible Capacity Btu [kW]
Net Latent Capacity Btu [kW]
Net System Power kW
Heating Performance [Heat Pumps]
High Temp. Btuh [kW] Rating
System Power KW / COP
Low Temp. Btuh [kW] Rating
System Power KW / COP
HSPF (Btu/Watts-hr)
Compressor
No/Type
Outdoor Sound Rating (dB)
5
Outdoor Coil - Fin Type
Tube Type
Tube Size in. [mm] OD
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Indoor Coil - Fin Type
Tube Type
Tube Size in. [mm]
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Drain Connection No./Size in. [mm]
Outdoor Fan - Type
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
CFM [L/s]
No. Motors/HP
Motor RPM
Indoor Fan - Type
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
No. Motors
Motor HP
Motor RPM
Motor Frame Size
Filter - Type
Furnished
(NO.) Size Recommended in. [mm x mm x mm]
Refrigerant Charge Oz. [g]
Weights
Net Weight lbs. [kg]
Ship Weight lbs. [kg]
NOTES:
1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. AHRI capaci-
ty is net and includes the effect of fan motor heat. Units are suitable for operation in CFM range shown in airflow tables. Units are certified in accordance with the Unitary
Air Conditioner Equipment certification program, which is based on AHRI Standard 210/240 or 360.
2. EER and/or SEER are rated at AHRI conditions and in accordance with DOE test procedures.
3. Heating Performance is rated at 47° F ambient, 70° F entering dry bulb for High Temp rating and 17° F ambient, 70° F entering dry bulb for Low Temp rating. Performance
ratings do include the effect of fan motor heat.
4. Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270.
A037CK
A037JK
36,000 [10.55]
36,000 [10.55]
12/14
12/14
1200/1200 [566/566]
1200/1200 [566/566]
35,400 [10.37]
35,400 [10.37]
27,600 [8.09]
27,600 [8.09]
7,800 [2.29]
7,800 [2.29]
3.05
3.05
34,200 [10.02]
34,200 [10.02]
2.78/3.6
2.78/3.6
19,000 [5.57]
19,000 [5.57]
2.48/2.24
2.48/2.24
8
8
1/Scroll
1/Scroll
76
76
Louvered
Louvered
Rifled
Rifled
0.375 [9.5]
0.375 [9.5]
12.65 [1.18]
12.65 [1.18]
1 / 20 [8]
1 / 20 [8]
TX Valves
TX Valves
Louvered
Louvered
Rifled
Rifled
0.375 [9.5]
0.375 [9.5]
4.33 [0.4]
4.33 [0.4]
3 / 13 [5]
3 / 13 [5]
TX Valves
TX Valves
1/1 [25.4]
1/1 [25.4]
Propeller
Propeller
1/24 [609.6]
1/24 [609.6]
Direct/1
Direct/1
3200 [1510]
3200 [1510]
1 at 1/3 HP
1 at 1/3 HP
850
850
FC Centrifugal
FC Centrifugal
1/10x9 [254x229]
1/10x9 [254x229]
Direct/2
Direct/2
1
1
1/2
1/2
1050
1050
48
48
Field Supplied
Field Supplied
No
No
(1)1x24x24 [25x610x610]
(1)1x24x24 [25x610x610]
93 [2637]
93 [2637]
356 [161]
356 [161]
380 [172]
380 [172]
A042CK
A042JK
Continued ->
44,000 [12.89]
44,000 [12.89]
11.85/14
11.85/14
1400/1450 [661/684]
1400/1450 [661/684]
43,000 [12.6]
43,000 [12.6]
31,800 [9.32]
31,800 [9.32]
11,200 [3.28]
11,200 [3.28]
3.63
3.63
38,500 [11.28]
38,500 [11.28]
3.31/3.4
3.31/3.4
21,800 [6.39]
21,800 [6.39]
3/2.06
3/2.06
8
8
1/Copeland Scroll
1/Copeland Scroll
78
78
Louvered
Louvered
Rifled
Rifled
0.375 [9.5]
0.375 [9.5]
16.54 [1.54]
16.54 [1.54]
1 / 22 [9]
1 / 22 [9]
TX Valves
TX Valves
Louvered
Louvered
Rifled
Rifled
0.375 [9.5
0.375 [9.5]
5.78 [0.54]
5.78 [0.54]
3 / 13 [5]
3 / 13 [5]
TX Valves
TX Valves
1/1 [25.4]
1/1 [25.4]
Propeller
Propeller
1/24 [609.6]
1/24 [609.6]
Direct/1
Direct/1
4200 [1982]
4200 [1982]
1 at 1/3 HP
1 at 1/3 HP
1075
1075
FC Centrifugal
FC Centrifugal
1/11x9 [279.4x228.6]
1/11x9 [279.4x228.6]
Direct/2
Direct/2
1
1
3/4
3/4
1050
1050
48
48
Field Supplied
Field Supplied
No
No
(1)1x24x24 [25x610x610]
(1)1x24x24 [25x610x610]
128 [3629]
128 [3629]
408 [185]
408 [185]
434 [197]
434 [197]
19