Download Print this page

Lister SB 113 H Instruction Manual page 12

Retrofit kit heating cable

Advertisement

Available languages

Available languages

Heating Cable Installation Instructions SB112H/113H
Important Notes
When installing, use sharp-edged tools
The connection to the mains must be carried out by authorized personnel
For the best possible protection of people, animals and equipment, a residual
current circuit breaker (FI 30 mA) is required.
WARNING !
The heating cable HKSB 24V / RBH may only use a safety low voltage transformer
with max. 24 Volt
Connect the heating cable HKSB 230V / RBH directly to the current supply (e.g.
junction box). Alternatively, a commercially available grounded plug can be fixed
to the cable ends.The grounding of the cable is not essential, because it is a class
II product (double insulated, no earth wire available).
1. The heating cable retrofit kit consists
of the heating cable and the heating
cable cover with a thermostat holder.
Heating cable with thermostat has
been clipped into the heating cable
cover (pre-assembled)
Nameplate must be on the right side.
3. You can put down the cover backwards
right after you pressed the heating cable
into the upper part of the guide groove.
2. Place the heating cable cover together with
the heating cable on the rear part of the bowl.
Hold the heating cable cover and the heating
cable with your left hand and press the heating
cable into the left guide groove of the bowl.
(See arrow)

Advertisement

loading

Related Products for Lister SB 113 H

This manual is also suitable for:

Sb 112 h zpsSb 112 hSb 113 h zps