Advertisement

Quick Links

NI-9260

Advertisement

Table of Contents
loading

Summary of Contents for National Instruments 9260

  • Page 1 NI-9260...
  • Page 2 GETTING STARTED GUIDE NI 9260 2 AO, 3 Vrms, 24 Bit, 51.2 kS/s/ch Simultaneous...
  • Page 3: Safety Guidelines

    This document explains how to connect to the NI 9260. In this document, the NI 9260 with BNC and the NI 9260 with mini XLR are referred to inclusively as the NI 9260. Before you begin, complete the software and...
  • Page 4: Safety Guidelines For Hazardous Voltages

    Do not mix hazardous voltage circuits and Caution human-accessible circuits on the same module. Ensure that devices and circuits connected to Caution the module are properly insulated from human contact. NI 9260 Getting Started Guide | © National Instruments | 3...
  • Page 5: Safety Guidelines For Hazardous Locations

    Safety Guidelines for Hazardous Locations The NI 9260 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx nA IIC T4 and Ex nA IIC T4 hazardous locations; and nonhazardous locations only.
  • Page 6 Zone 2 hazardous locations, in ambient temperatures of -40 °C ≤ Ta ≤ 70 °C. If you are using the NI 9260 in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex nC IIC T4, Ex IIC T4, Ex nA IIC T4, or Ex nL IIC T4 equipment.
  • Page 7: Electromagnetic Compatibility Guidelines

    To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation. 6 | ni.com | NI 9260 Getting Started Guide...
  • Page 8 In addition, take precautions when designing, selecting, and installing measurement probes and cables to ensure that the desired EMC performance is attained. NI 9260 Getting Started Guide | © National Instruments | 7...
  • Page 9: Preparing The Environment

    Preparing the Environment Ensure that the environment in which you are using the NI 9260 meets the following specifications. Operating temperature -40 °C to 70 °C (IEC 60068-2-1, IEC 60068-2-2) Operating humidity 10% RH to 90% RH, (IEC 60068-2-78) noncondensing...
  • Page 10 NI 9260 Pinout CHASSIS GND AO0+ AO0+ AO0- AO0- CHASSIS GND A10+ AO1+ AO1- A10- NI 9260 Getting Started Guide | © National Instruments | 9...
  • Page 11 Description Positive analog output signal connection Negative analog output signal connection Chassis GND Chassis ground connection NI 9260 with mini XLR Analog Output Connection CHASSIS NI 9260 with mini XLR Load 10 | ni.com | NI 9260 Getting Started Guide...
  • Page 12 Refer to the Circuitry section in the device datasheet on ni.com/manuals for further information. NI 9260 with BNC Analog Output Connections 50 Ω IN-/GND Load NI 9260 with BNC NI 9260 Getting Started Guide | © National Instruments | 11...
  • Page 13: Overvoltage Protection

    NI 9260 Connection Guidelines • Make sure that devices you connect to the NI 9260 are compatible with the module specifications. • To minimize ground noise, make sure you connect the chassis ground to earth ground. Overvoltage Protection The NI 9260 provides overvoltage protection for each channel.
  • Page 14: Where To Go Next

    NI 9260 Datasheet NI-RIO Help NI-DAQmx Help LabVIEW FPGA Help LabVIEW Help RELATED INFORMATION C Series Documentation Services & Resources ni.com/services ni.com/info cseriesdoc Located at ni.com/manuals Installs with the software NI 9260 Getting Started Guide | © National Instruments | 13...
  • Page 15: Worldwide Support And Services

    (EMC) and product safety. You can obtain the DoC for your product by visiting ni.com/certification. If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration. 14 | ni.com | NI 9260 Getting Started Guide...
  • Page 16 United States, visit the Worldwide Offices section of ni.com/niglobal to access the branch office websites, which provide up-to-date contact information, support phone numbers, email addresses, and current events. NI 9260 Getting Started Guide | © National Instruments | 15...
  • Page 17 U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. © 2015—2016 National Instruments. All rights reserved. 376926D-01 Mar16...

Table of Contents