  • Page 1 NI-9260 Getting Started 2022-07-12...
  • Page 2: Table Of Contents

    NI 9260 Pinout............. . . 7 NI-9260 with mini XLR Analog Output Connection....... 7 NI 9260 with BNC Analog Output Connections.
  • Page 3: Overview

    NI-9260 Getting Started Overview This document explains how to connect to the NI-9260. In this document, the NI-9260 with BNC and the NI-9260 with mini XLR are referred to inclusively as the NI-9260. Note Before you begin, read the NI-9260 Safety, Environmental, and Regulatory Information document on ni.com/manuals...
  • Page 4: Safety Guidelines For Hazardous Voltages

    Safety Guidelines for Hazardous Locations The NI-9260 is suitable for use in hazardous locations; , and hazardous locations; and nonhazardous locations only. Follow these guidelines if you are installing the NI-9260 in a potentially explosive environment. Not following these guidelines may result in serious injury or death.
  • Page 5 Each NI-9260 is marked and is suitable for use in Zone 2 hazardous locations, in ambient temperatures of -40 °C ≤ Ta ≤ 70 °C. If you are using the NI-9260 in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex nC IIC T4, Ex IIC T4, Ex nA IIC T4, or Ex nL IIC T4 equipment.
  • Page 6: Electromagnetic Compatibility Guidelines

    EMC performance is attained. Preparing the Environment Ensure that the environment in which you are using the NI-9260 meets the following specifications. Operating temperature (IEC 60068-2-1, IEC 60068-2-2) -40 °C to 70 °C...
  • Page 7: Ni 9260 Pinout

    AO0+ AO0– AO0– CHASSIS GND A10+ AO1+ AO1– A10– Signal Description Positive analog output signal connection Negative analog output signal connection Chassis GND Chassis ground connection Table 1. Signal Descriptions NI-9260 with mini XLR Analog Output Connection © National Instruments...
  • Page 8: Ni 9260 With Bnc Analog Output Connections

    IN–/GND Load NI 9260 with BNC AO– NI-9260 Connection Guidelines Make sure that devices you connect to the NI-9260 are compatible with the ■ module specifications. To minimize ground noise, make sure you connect the chassis ground to ■ earth ground.
  • Page 9: Where To Go Next

    NI-9260 Getting Started Note Refer to the NI-9260 Specifications on ni.com/manuals for more information about overvoltage protection. Where to Go Next CompactRIO NI CompactDAQ NI 9260 Datasheet NI 9260 Datasheet NI-RIO Help NI-DAQmx Help LabVIEW FPGA Help LabVIEW Help RELATED INFORMATION...