Electrical System
Maintenance

Electrical System Safety

Disconnect the battery before repairing the
g305646
machine. Disconnect the negative terminal first
and the positive last. Connect the positive terminal
first and the negative last.
Charge the battery in an open, well-ventilated
area, away from sparks and flames. Unplug the
charger before connecting or disconnecting the
battery. Wear protective clothing and use insulated
tools.

Servicing the Battery

Removing the Battery
WARNING
Incorrectly removing the cables from battery
could damage the machine and cables,
causing sparks. Sparks can cause the battery
gasses to explode, resulting in personal
injury.
• Always disconnect the negative (black)
battery cable before disconnecting the
positive (red) cable.
• Always connect the positive (red) battery
cable before connecting the negative
g027518
(black) cable.
1.
Park the machine on a level surface, disengage
the blade-control switch (PTO), and engage the
parking brake.
2.
Shut off the engine, remove the key, and wait
for all moving parts to stop before leaving the
operating position.
3.
Loosen the 2 fasteners on the battery cover
counterclockwise 1/4 turn, and remove the
battery cover
36
(Figure
45).