7.12 Programming menu
GENERAL
The programming menu can be accessed via the integrated reset
push-button, during OPERATION and in STAND-BY.
If in page menu the reset push-button is not pressed within 10
seconds the page will be automatically be exited and there will be
a green led flashing for the time set.
BLOCK DIAGRAM FOR ENTERING THE MENU
BURNER STATE
TYPE OF
OPERATION
FUNCTION
SWITCHING OFF
PUSH-BUTTON
5 SEC.
RELEASE TIME
NUMBER
2 RED
OF BLINKS
OF THE LED
OUTLET
OUTLET
AUTOMATIC
S9278
Push-button
Function
release time
5s t < 10s
Shut-down test
10s t < 15s
Post-
purging
20s t < 25s
Intermittent
operation
25s t < 30s
Last lockout
memorised
20115639
Start-up, calibration and operation of the burner
OPERATION (WITH FLAME) AND STAND-BY
POST
PURGING
10 SEC.
1 GREEN
10 SEC. AFTER
RELEASE
No. of blinks of
No. of pressings
the led per
of the reset push-
menu page
button
2 blinks
/
RED
none
1 blink
1 = 10 sec.
GREEN
2 = 20 sec.
3 = 30 sec.
4 = 60 sec. (default)
5 = 120 sec.
6 = 0 sec. (deactivated)
3 blinks
1 = 0 disabled
GREEN
2 = 1 hour
3 = 24 hours (default)
4 blinks
/
GREEN
none
If the number of presses on the reset push-button exceeds the
maximum allowable, the value that stays in memory will be the
maximum one.
If the reset push-button is pressed for more than 60 seconds, a
push-button error will be displayed and the control-box will re-
start.
INTERMITTENT
OPERATION
20 SEC.
3 GREEN
10 SEC. AFTER
RELEASE
No. of blinks of
the Led (green)
/
none
1 blink
2 blinks
3 blinks
4 blinks
5 blinks
6 blinks
1 blink
2 blinks
3 blinks
Displaying the type
of lockout accord-
ing to the table sec-
tion 7.10.2
26
GB
LAST LOCKOUT
MEMORISED
25 SEC.
4 GREEN
10 SEC. AFTER
RELEASE
Fig. 24
Quitting the menu
Automatic, at the
end of the blinking
10 sec. after the release of
the push-button
10 sec. after the release of
the push-button
10 sec. after the release of
the push-button
Tab. G