6 Electrical installation
Item
X5M
X6M
X7M, X8M
X10M
M4 (earth)
6.3

Connections to the indoor unit

Item
Power supply (main)
See
"6.3.1 To connect the main power
supply" [ 4  13].
Power supply (backup
See
"6.3.2 To connect the backup heater
supply" [ 4  14].
heater)
power
Shut-off valve
See
"6.3.3 To connect the shut-off
valve" [ 4  16].
Electricity meters
See
"6.3.4 To connect the electricity
meters" [ 4  16].
Domestic hot water
See
"6.3.5 To connect the domestic hot
pump" [ 4  16].
pump
water
Alarm output
See
"6.3.6 To connect the alarm
output" [ 4  17].
Space cooling/heating
See
"6.3.7 To connect the space cooling/
operation control
heating ON/OFF
Changeover to
See
"6.3.8 To connect the changeover to
external heat source
external heat
control
Power consumption
See
"6.3.9 To connect the power
digital inputs
consumption digital
Safety thermostat
See
"6.3.10 To connect the safety
thermostat (normally closed
contact)" [ 4  19].
Smart Grid
See
"6.3.11 To connect a Smart
Grid" [ 4  19].
WLAN cartridge
See
"6.3.12 To connect the WLAN
cartridge (delivered as
Room thermostat
See below table.
(wired or wireless)
Wires: 0.75 mm²
Maximum running current: 100 mA
For the main zone:
▪ [2.9] Control
▪ [2.A] Ext thermostat type
For the additional zone:
▪ [3.A] Ext thermostat type
▪ [3.9] (read-only) Control
Installation manual
12
Tightening torque (N•m)
0.88 ±10%
2.45 ±10%
2.45 ±10%
0.88 ±10%
1.47 ±10%
Description
output" [ 4  17].
source" [ 4  18].
inputs" [ 4  18].
accessory)" [ 4  21].
Item
Heat pump convector
There are different controllers and
setups possible for the heat pump
convectors.
Depending on the setup, you also
need to implement a relay (field
supply, see addendum book for
optional equipment).
For more information, see:
▪ Installation manual of the heat
▪ Installation manual of the heat
▪ Addendum
Wires: 0.75 mm²
Maximum running current: 100 mA
For the main zone:
▪ [2.9] Control
▪ [2.A] Ext thermostat type
For the additional zone:
▪ [3.A] Ext thermostat type
▪ [3.9] (read-only) Control
Remote outdoor
See:
sensor
▪ Installation manual of the remote
▪ Addendum
Wires: 2×0.75 mm²
[9.B.1]=1 (External sensor =
Outdoor)
[9.B.2] Ext. amb. sensor offset
[9.B.3] Averaging time
Remote indoor sensor
See:
▪ Installation manual of the remote
▪ Addendum
Wires: 2×0.75 mm²
[9.B.1]=2 (External sensor = Room)
[1.7] Room sensor offset
Human Comfort
See:
Interface
▪ Installation and operation manual of
▪ Addendum
Wires: 2×(0.75~1.25 mm²)
Maximum length: 500 m
[2.9] Control
[1.6] Room sensor offset
Description
pump convectors
pump convector options
book
for
optional
equipment
outdoor sensor
book
for
optional
equipment
indoor sensor
book
for
optional
equipment
the Human Comfort Interface
book
for
optional
equipment
ETBH/X16E