Graco ProMix Auto Service Parts page 25

Hide thumbs Also See for ProMix Auto:
Table of Contents

Advertisement

Servicing Fluid Manifold
There are two different size integrators: 50cc and
25cc. 25cc is etched on the outside of the 25cc
integrator component.
Removing
1.
Follow
Servicing Flow Meters
1-7, page 24.
2.
Disconnect air and fluid lines from the manifold (5).
3.
Remove 4 screws (34). To ease screw removal,
use a long T-handle Allen wrench.
4.
Remove A and B meter bracket screws.
5.
Remove the 3 screws behind the fluid manifold.
6.
Remove fluid manifold (5).
7.
Service fluid manifold as instructed in the Fluid Mix
Manifold manual.
311189C
Installing
1.
2.
3.
4.
procedure, steps
F
Install the 3 screws behind the fluid manifold.
Secure fluid manifold (5) and mounting plate (35)
with 4 screws (34).
Install A and B meter (1) bracket screws. See steps
9-11,Installing, Page 24.
Connect air and fluid lines.
. 29
IG
Service
5
34
35
TI4859a