Shutdown - Graco ProMix Auto Service Parts

Hide thumbs Also See for ProMix Auto:
Table of Contents

Advertisement

Shutdown

To avoid electric shock, turn off EasyKey™ power
before servicing.
Servicing EasyKey™ display exposes you to high
voltage. Shut off power at main circuit breaker
before opening enclosure.
All electrical wiring must be done by a qualified
electrician and comply with all local codes and reg-
ulations.
Do not substitute system components as this may
impair intrinsic safety.
Overnight Shutdown
There are two possible procedures for overnight shut-
down:
If flushing the system with solvent is required,
run Recipe 0 to purge solvent through meters
and gun; see ProMix
(311079).
If flushing the system with solvent is NOT
required, release the gun trigger and put system
in Standby mode.
Service Shutdown
1. Follow "Pressure Relief Procedure" on page 10.
2. Close main air shutoff valve on air supply line and
on ProMix™ Auto.
311189C
Auto Operation manual
3. Shut off ProMix™ Auto power (0 position). F
4. If servicing EasyKey™ Display, also shut off power
at main circuit breaker.
F
. 4
IG
Shutdown
. 4.
IG
0 = OFF
11

Advertisement

Table of Contents
loading

Table of Contents