4 Quick guide

4.1 User permission level

4.2 Domestic hot water

EKHWET90+120B
R32 Split series – Domestic hot water tank
4P680076-1A – 2022.11
The amount of information you can read and edit in the menu structure depends
on your user permission level:
User: Standard mode
Advanced user: You can read and edit more information
To change the user permission level
1 Go to [B]: User profile.
B
User profile
2 Enter the applicable pin code for the user permission level.
Browse through the list of digits and change the selected digit.
Move the cursor from left to right.
Confirm the pin code and proceed.
User pin code
The User pin code is 0000.
User
0000
Advanced user pin code
The Advanced user pin code is 1234. Additional menu items for the user are
now visible.
Advanced user
1234
To turn tank heating operation ON or OFF
NOTICE
Disinfection mode. Even if you turn OFF tank heating operation ([C.3]: Operation >
Tank), disinfection mode will remain active. However, if you turn it OFF while
disinfection is running, an AH error occurs.