Cord-And-Plug Installation - Siemens VersiCharge SG VCSG30GRYUW Installation And Operation Manual

Table of Contents

Advertisement

DANGER
Explosion hazard. This equipment has arcing or sparking parts that should not
be exposed to flammable vapors. This equipment should be installed at least 18 inches
above floor or ground level. Use extreme caution and follow instructions carefully.

3.3 Cord-and-plug installation

The standard VersiCharge SG unit arrives factory-configured for rear fed and bottom fed
cord-and-plug installations. For hardwired installations, please refer to section 3.4 of this
manual. Please note that once the cord is removed, it shall not be reinstalled on the unit,
otherwise the warranty will be voided.
WARNING!
rated receptacle and enclosure, when installed outdoors. Installing outdoors without
properly rated outdoor receptacles and enclosures will violate listings and void the device
warranty. Outdoor cord-and-plug installations must be bottom fed only.
Bottom-fed, Cord-and-Plug Installation
 Measure the plug in cord of the unit first since the mounting bracket and the receptacle
need to be located within this distance of each other.
 Locate a stud within the wall to attach
the mounting bracket.
For concrete or masonry walls,
o
install appropriate anchors.
Verify that the stud or anchor and
o
surrounding materials can handle the
20+ lbs load of the VersiCharge.
 Receptacle will be located below
VersiCharge mounting bracket, either to
the left or the right of the stud to which
the mounting bracket will be attached.
Verify receptacle location complies with
local code requirements.
NEC® 2014 specifies: Indoor (NEC®
o
Article 625.29B) installation 18 – 48
inches above ground level.
Verify local code with respect to
o
installation height.
 Wire a standard NEMA 6-50 receptacle
using appropriate wire.
 Using 7/16 inch socket head and drill, attach the mounting bracket to the wall using two
lag screws provided. Verify that lag screws are going into the stud.
15
Due to risk of moisture, cord-and-plug installations require a NEMA outdoor
©
2015 Siemens Industry, Inc.
R814365 Rev05