9.1.3.
Adjustment Procedure
All adjustments except "Touch Panel Calibration" and "Factory Setting" performs using "14 Adjustment function for the service" in
service mode menu.
"Touch Panel Calibration" is performed using 16 of service mode menu and "Factory Setting" is performed using 1 of service mode
menu. Refer to "6 Service mode" and "10 Factory Setting".
[Execute adjustment function for service]
1. Set the power switch to ON, and turn to ON.
2. While pressing the "MENU"button to "FOCUS ASSIST"button and "Zoom lever" (or "Sub zoom lever") to W side for more than
3 seconds until the top screen of the Service Mode Menu being displayed.
3. Touch the
twice then touch the [14] of LCD.
4. Touch the [YES] of LCD.
52