TECHNICAL CHARACTERISTICS

TECHNICAL DATA FGP 50/2 EVO-2

MODEL
Flow min. 1°st. / min. 2°st. - max. 2°st. *
Thermal power min. 1°st. / min. 2°st. - max. 2°st. *
Thermal power min. 1°st. / min. 2°st. - max. 2°st. *
Fuel: LIGHT-OIL 1.5°E at 20°C = 6.2 cSt = 35 sec Redwood N°1
Intermitted working operation (min. 1 stop every 24 hours) two stages
Environmental conditions operation / storage:
Max. temperature combustion air
Nominal electric power
Fan motor
Nominal motor current absorption
Nominal auxiliary absorption
Power supply:
Electric protection degree:
Noisiness ** min-max
Burner weight ***
* Reference conditions: Environment temperature 20°C - Barometric pressure 1013 mbars - Altitude 0 metre (sea level).
** Measured sonourous pressure in the combustion lab, with funcional burner on beta boiler in a distance of 1 m (UNI EN ISO 3746).
*** For burner FGP 50/2 EVO-2 with long head add 1 kg to the weight.

OPERATING RANGE DIAGRAM FGP 50/2 EVO-2

[mbar]
12
10
8
6
4
2
0
0
The firing rates has been obtained based on test boilers in accordance with EN267 standards and are indicative of matching the burner to the boiler.
For the correct operation of the burner, combustion chamber dimensions must be in accordance with current regulation. In case of non-compliance,
contact the manufacturer.
FGP 50/2 EVO-2
TECHNICAL CHARACTERISTICS
100
300
200
Fig. 1
X = Thermal power Y = Pression in the combustion chamber
[kg/h]
[Mcal/h]
100.1/204-541.8
[kW]
-15...+40°C / -20...+70°C, rel. humidity max. 80%
[°C]
[kW]
[kW]
[A]
[A]
3~400V, 1N~230V - 50Hz
[dBA]
[kg]
400
500
600
070002_3_B
FGP 50/2 EVO-2
9.9/20-53.1
117.4/237-630
60
1.1
0.74
1.8
0.3
IP 40
71-73
31
700
[kW]
2