FOR CONTROL BOX #0
The factory defaults for all settings are shown in the Quick Reference Chart below. If these are acceptable, the driver board is ready for use. If
changes are required, follow the instructions to make adjustments.
Symbol
Function
d
Sensor
Sensitivity
Auto Timer
T
(faucet shut-off)
R
Rinse Cycle
Rinse Time
r
b
Buzzer
M
Metering Mode
Function
MODE

BATTERY STRENGTH INDICATOR

To check the battery strength:
Press and hold MODE (yellow pushbutton on left hand side). After 5 seconds the battery strength will be displayed:
● FUL - Healthy
● MID - Average
● Lo_ - Low Average
● bAd - Replace Batteries (buzzer will annunciate and LED will blink if activated - if these features are turned on)
If you have any questions about the installation of this product or need help troubleshooting this product, please call Delta Commercial Technical
Services at 1-800-387-8277 (Canada) or 1-877-509-2680 (U.S.A.).

MAKING ADJUSTMENTS

DRIVER BOARD QUICK REFERENCE CHART
Description
Higher numbers represent a more sensitive configuration. Higher
sensitivity will increase the distance at which the user is detected.
The sensitivity settings are on a 10 point scale (1 - 10). Please
note that these setting values are relative values and do not
correspond to a particular distance.
Auto Timer is a safety mode in the event the sensor continually
senses a target. In this case, the faucet will stop after the pre-
determined time period expires.
This feature is meant to purge stagnant water from supply lines.
The faucet will turn on after the set amount of hours of inactivity
and run the set Rinse Time (r) (see below).
This feature is only active if a Rinse Cycle (R) time is chosen. The
setting determines how long the faucet will turn on during the
Rinse Cycle (R).
For Proximity, the buzzer setting does not silence the controller
and sensor status annunciations. Buzzer options are ON and
-(OFF), the default setting is ON.
This feature changes the product into a metering faucet; it will run
the full set amount of time after the user's hands are first detected.
Note: Auto Timer (T) is disabled when the feature is turned on.
Function
Setting
TOGGLE
To adjust settings, press and hold MODE (yellow pushbutton on left
hand side) until the Function symbol appears. Once in Adjustment
Mode, keep pressing MODE until desired Function is reached (see
Quick Reference Table). To change Function Setting, press and
release TOGGLE (white pushbutton on right hand side) until desired
Function Setting is reached (see Quick Reference Table).
Note: Controller will leave Adjustment Mode after 5 seconds of
inactivity.
w w w . s p e c s e l e c t . c o m
Page 6
Factory
Function Settings
Default Setting
Sensitivity setting
1 to 10
5
5, 7, 10, 12, 15, 30, 45, 60, 75, 90
45 seconds
seconds
2.0, 3.0, 4.0, 5.0, 6.0, 7.0, 8.0, 9.0,
9.9 minutes
- (OFF), 6, 12, 18, 24, 30, 36,
--
42, 48 hours
10 seconds
10, 20, 30, 40, 50, 60, 90 seconds
(once enabled)
2.0, 2.5, 3.0 minutes
ON, - (OFF)
ON
-- (OFF), 7, 8, 9, 10, 11, 12, 13,
--
14, 15, 18, 24, 30, 40, 50, 60, 90
seconds
2.0, 2.5, 3.0, 3.5, 4.0 minutes