Remove/Replace Solenoid - Silver King SK-1-C1 Service Manual

Cream dispenser
Table of Contents

Advertisement

Cream Dispenser
Model SK-1-C1
Remove Solenoid
Unplug the unit. Remove cream bin from unit.
1
Failure to disconnect power
from the unit before servicing
could result in severe bodily
injury or death. The ON/OFF
Remove the drip tray from the unit
2
Loosen the (4) screws to remove front cover and ac-
3
cess the electronics. Reference the
Press on tab and pull straight to remove the display
4
cable. Reference the
Set front fascia aside.
5
Remove Solenoid connector from main board. Refer to
6
the
Green Arrow
Loosen the (2) thumbscrews to free the solenoid.
7
Carefully pull out wiring. Refer to the
Replace Solenoid
Reinstall (2) thumbscrews to secure solenoid to unit.
1
Previously removed in step 7.
Reconnect solenoid connection to board. Previously
2
removed in step 6
Reinstall the display cable. Previously removed in
3
step 4.
WARNING
Red
Arrows.
Yellow Arrow
Blue
Arrows.
Reinstall the front fascia onto unit. Ensure (4) screws
4
are secure. Previously removed in step 3
Reinstall drip tray and creamer bin. Plug in unit. Verify
5
functionality of unit.