Register Plates - Dean Forge Sherford 8 Operating Instructions Manual

Table of Contents

Advertisement

Register plates

Chimneys without continuous flue to the top , must have the register a plate made of 1.5mm
steel treated to prevent corrosion (BS8303 part 3 9.5)
Register plates made of fireboard may only be used if a liner or flue runs from the top of the
stove to the top of the chimney without a break. Always check the current building regulations.
Flue Connections and Outlets
Dean Stoves can be flued from the top and the back, or with a vertical back box. Horizontal
flue from back of stove should not exceed 150mm.
All flue connections must be sealed. Doors in the register plate must be present or a soot box
fitted in the back or side of the fireplace to enable access to clean the chimney when the stove
is installed without a flue liner.
If the chimney has been lined and cannot be swept through the stove an access door on the first
length of flue must be installed for cleaning access.
The Sherford 8 SE model requires a 150mm (6") first length of flue then connecting to a
minimum of 150mm (6") liner. The installation of a flue liner is recommended.
Diagrams showing the flue outlet from the top (A), back (B) and back box (C).
X = Position of baffle plate
Y = Back protection brick
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sherford 8 se

Table of Contents