Page 1
No. 100, Sec. 2, Daqing St., South Dist., Taichung City 40242, Taiwan Ontario, CA 91761, USA Tel: +886 4 2369 2388 Tel: +1 888 481 8485 Max Tel Fax: +886 4 2261 7586 Fax: +1 909 781 6970 Email: info@bionime.com http: //www.bionimeusa.com http://www.bionime.com...
Page 3
Thank you for choosing our product. This manual contains all the information you need to use RIGHTEST Blood Glucose Monitoring System Max Tel is intended to be used for the quantitative your product to get accurate blood glucose test results. Please read this entire manual before measurement of glucose (sugar) in fresh capillary whole blood samples drawn from the fingertips, you get started with any testing.
Page 4
Samples smaller than 0.75 µL will cause Er4. If this occurs, repeat the test with a new test strip. - The Blood Glucose Meter Max Tel can only be used with extra spacing Blood Glucose Test Strips Max. Test strips from other brands should not be used under any circumstances. The use of test strips from other brands may give inaccurate results.
Page 5
Limitations Limitations - To avoid potential electromagnetic interference, keep the meter away from electromagnetic - The RIGHTEST Blood Glucose Monitoring System Max Tel is not intended for serum or plasma testing. radiation sources such as X-rays or MRI. - Do not use at altitudes greater than 10,000 feet (3,048 meters).
Page 6
- Modification of the System is Not Allowed: Do not modify or tamper with any - Trouble Shooting If any situation not mentioned in this user manual happens, please components or accessories of the Max Tel. All components of the Max Tel are not contact your healthcare professional or Customer Service.
Table of Contents Table of Contents About RIGHTEST Blood Glucose Monitoring System Max Tel Quality Control About Quality Control Testing RIGHTEST Blood Glucose Monitoring System Max Tel Performing a Quality Control Test RIGHTEST Blood Glucose Meter Max Tel RIGHTEST Blood Glucose Test Strip Max...
Front View of Meter B ack View of Meter Sample Entry Depth Adjustable Cap Release Button 1. RIGHTEST Blood Glucose Meter Max Tel (with Li-polymer battery, type C cable, 5V adapter) Test strip Lancing Device View Window Lancet Carrier Safety Switch Plunger 2.
RIGHTEST Blood Glucose Meter Max Tel RIGHTEST Blood Glucose Meter Max Tel Test Strip Port Touch Panel USB Charging Port USB Charging Port SIM Card Port SIM Card Port Meter Label Main Button...
Page 10
RIGHTEST Blood Glucose Meter Max Tel RIGHTEST Blood Glucose Meter Max Tel Home Page Indicates that the current battery status. Larger black areas means the battery is more charged, and vice versa. When the black areas becomes smaller or empty, please charger your meter.
RIGHTEST Blood Glucose Test Strip Max RIGHTEST Blood Glucose Test Strip Max The RIGHTEST Blood Glucose Meter Max Tel can only be used with RIGHTEST Blood Glucose Test Strips Max and RIGHTEST Control Solution GC700. The use of other test strips or control Electrode Contacts solutions may lead to incorrect results.
Before Getting Started Before Getting Started 1. Connect the USB-C Plug of the charging cable to the USB-C input of Charging Basics the receiver. Before using the system for the first time, charge the meter for a complete charging cycle without interruption.
Turning On / Off the Meter Meter Setting 1. How to turn on the meter Initial setting Press and hold the main button for about 2 seconds or insert a test strip. When the meter is turned on for the first time, it will go into the setting process automatically. Follow the on-screen instructions to complete and save your own setting.
Meter Setting Turn On/Off Flight Mode Turn on/off flight mode LTE connection Before turn on the meter, please make sure that you have installed the sim card. The LTE Turn on/off "Flight Mode" in "Setting." Setting Set Flight mode connection will start automatically when the meter is turned on. If the LTE connection is successful, the date and time will be auto-set according to the LTE signal, and can't be change CS mode manually by user.
Handling RIGHTEST Blood Glucose Test Strips Max Handling RIGHTEST Blood Glucose Test Strips Max Inserting a test strip: Removing a test strip: 1. Hold the test strip between your thumb and middle finger with the View 1. Hold the test strip as shown.
Performing a Blood Glucose Test Performing a Blood Glucose Test 7. Rotate the clear top part of the cap to adjust the depth. Depth Adjustable Cap Release Button Check the number of lines visible in the View Window. More lines correspond to a greater depth. Try: Plunger "...
Page 17
Performing a Blood Glucose Test Performing a Blood Glucose Test 11. Once the strip insert, the meter will switch to the 15. The screen will display a countdown timer. Your test Apply Blood Sample testing mode, the screen will display with "Checking" result will be displayed after 5 seconds.
Performing a Blood Glucose Test Setting Markers After 5 seconds countdown, the test result and test date and time CAUTION will be displayed, along with 4 status markers below the result. - Do not apply the blood sample before you see "Apply Blood Sample" appear. The meter By tapping the marker you want to set, different options will be is performing an internal check.
(For detailed information, refer to the Forearm If the LTE is not connected when RIGHTEST Lancing Device insert.) the result is saved, the result will be - To increase blood flow, massage the intended puncture stored in the meter.
View Window Appearance Alternative Site Testing To obtain an accurate test result, ensure CAUTION that your blood sample covers the entire - Consult your healthcare professional before sampling from your palm or forearm. area of the View Window. An insufficient - Alternate site testing should be done only during steady-state times (when glucose is blood sample will result in an error message (Er4).
Understanding Test Results and Messages Understanding Test Results and Messages If your blood glucose result is unusually high or low, or if you have any doubts about your test The meter displays results between 10 and 600 mg/dL (0.6 and 33.3 mmol/L). results, repeat the test with a new test strip.
- RIGHTEST Blood Glucose Test Strip Max NOTE - RIGHTEST Control Solution GC700 - The RIGHTEST Control Solution GC700 is compatible with the RIGHTEST Blood Glucose Monitoring Systems Max Tel. If you want to purchase additional supplies please contact Bionime customer service.
About Quality Control Testing Performing a Quality Control Test 1. To perform a quality control test, tap the "Setting" on the home CAUTION Insert Strip CS mode page, and tap the "CS mode" to enter the mode. - Each time you open a new bottle of control solution, write the opening date on the label. 2.
Page 24
Performing a Quality Control Test Performing a Quality Control Test 9. Touch the test strip sample port to the drop. Move the meter, not CAUTION the cap. - Your Control Solution Test results will not be included in the average calculations but they 10.
Understanding Control Test Results Maintaining the Products Indirect transmission of Human Immunodeficiency Virus (HIV), Hepatitis B Virus (HBV) and The control solution tests should fall within the control solution range printed on the test strips label, which means the system is functioning properly. Hepatitis C Virus (HCV) during the delivery of healthcare services has been increasingly reported.
Page 26
Maintaining the Products Maintaining the Products Cleaning and disinfection frequency: at least once a week. Cleaning and disinfection frequency: at least once a week. To clean the meter: To clean the lancing device: 1. Wipe the whole surface of the meter using the disinfectant wipes listed 1.
Page 27
Maintaining the Products Recalling Test Results The RIGHTEST Blood Glucose Meter Max Tel can automatically store up to 1000 test results CAUTION along with the time and date. If your meter has 1000 stored results, the most recent test result - Users should wash their hands thoroughly with soap and water after handling the meter, will take the place of the oldest.
Recalling Average Test Results Recalling Average Test Results The RIGHTEST Blood Glucose Meter Max Tel provides several average test results. View the NOTE 1-day, 7-days, 14-days, 30-days, 60-days and 90-days average test results for better blood - The averaging function requires the correct time and date to be set. Test results must glucose monitoring.
Glucose Test Strip Max" to re-insert the unused test strip, or contact incorrectly. Or you inserted Please test between 6°C a wrong strip. 3. If your RIGHTEST Meter or Test Strips have been exposed to Customer Service for assistance. (43°F) and 44°C (111°F). Please retry with a correct test strip in the correct way.
Page 30
Error Messages and Troubleshooting Error Messages and Troubleshooting LTE Not Connected Testing Mode Error code Find a location covered with better LTE signal and tap "Retry". Error codes on this page are errors that may happen while performing a test. LTE Not Connected LTE network is unavailable.
Page 31
(2) Tap the "Reboot" on screen or press and hold the main button for about 2 seconds to turn off the meter. Please contact your local RIGHTEST Customer Service or email us at info@bionime.com. (3) If the meter did not reboot after tapping the "Reboot", or the screen does not pop out power off confirmation.
Sample turn off manually, press the main button for 3 seconds Operating Temperature 43 - 111°F (6 - 44°C) Minimum Sample Volume Refer to RIGHTEST Test Strip Max insert 10 - 90% Operating Relative Humidity Hematocrit Power Supply Non-replaceable and Rechargeable lithium battery (3.7V)
Specification Certificate Statement FCC STATEMENT Charging Port USB type C This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: Data Transmission (1) This device may not cause harmful interference; and (2) This device must accept any LTE network interference received, including interference that may cause undesired operation.
Page 34
Certificate Statement Certificate Statement Turning the equipment on and off in proximity to a radio or television will determine whether NCC STATEMENT the equipment is causing interference to signal reception. If interference is present, the user is encouraged to attempt to resolve it by one or more of the following methods: - 減少電磁波影響,請妥適使用...
This warranty does not apply to the performance of a RIGHTEST Blood Glucose Meter Max Tel diseases. Please follow your local regulations to properly dispose of the system (please that has been altered, misused, tampered with or abused in any way.
Bionime Customer Service. The chart below shows the results of a study where 350 typical users used the meter Max Tel to If abnormal behavior is observed due to EM disturbances, please contact the supplier or hospital test their blood glucose level.
(for home healthcare) specified below. GLUCOSE LEVEL INDICATION The customer or the user of the Max Tel, GM777 should assure that it is used in such an environment. From 70 to 99 mg/dL (3.9 to 5.5 mmol/L) Normal fasting glucose Electromagnetic environment-guidance From 100 to 125 mg/dL (5.6 to 6.9 mmol/L)
The Max Tel, GM777 is intended for use in the electromagnetic environment (for home healthcare) specified below. The customer or the user of the Max Tel, GM777 should assure that it is used in such an environment. Electromagnetic environment-guidance Emission test...
Need help?
Do you have a question about the Max Tel and is the answer not in the manual?
Questions and answers