Quantum DAT 160 User's Guide
• With single-ended (SE) SCSI, each signal travels over a single wire
and each signal's value is determined by comparing the signal to a
paired ground wire. Signal quality tends to decrease over longer
cable lengths or at increased signal speed.
• With low voltage differential (LVD) signaling, signals travel along
two wires and the difference in voltage between the wire pairs
determines the signal value. This enables faster data rates and longer
cabling with less susceptibility to noise than SE signaling and
reduced power consumption.
If you use LVD SCSI devices on the same bus as single-ended devices this
will switch the LVD SCSI host adapter into single-ended mode and
restrict cable length.
If you connect only LVD SCSI devices, the bus will operate in low voltage
differential mode and Ultra160 speeds will be enabled. You can use a
combination of Ultra160 and Ultra2 devices. Each device will operate at
its optimum speed.
Appendix B SCSI Configuration Guide