Field Settings; Procedure - Daikin VRV IV HXHD125AV1B Operation Manual

Indoor unit
Table of Contents

Advertisement

5.12. Field settings

The configuration of the Daikin system is done through field settings.
In this operation manual all field settings related to the operation of
the unit and user demand are explained. A list of all those field
settings and default values is given under
on page
19. In this same list, we provided for 2 columns to register
the date and value of altered field settings at variance with the default
value.
For a total list of field settings, refer to the installation manual.
All field settings are accessible and programmable through the user
interface on the indoor unit.
Each field setting is assigned a 3-digit number or code, for example
[5-03], which is indicated on the user interface display. The first digit
[5] indicates the 'first code' or field setting group. The second and
third digit [03] together indicate the 'second code'.

Procedure

To change one or more field settings, proceed as follows.
3
2
1
Press the
button for a minimum of 5 seconds to enter FIELD
SET MODE.
The
icon (3) will be displayed. The current selected field
setting code is indicated
the right
(1).
2
Press the
button to select the appropriate field setting
first code.
3
Press the
button to select the appropriate field setting
second code.
4
Press the
button and
the set value of the select field setting.
5
Save the new value by pressing the
6
Repeat step 2 through 4 to change other field settings as
required.
7
When finished, press the
INFORMATION
Changes made to a specific field setting are only stored
when the
button is pressed. Navigating to a new field
setting code or pressing the
change made.
HXHD125AV1B + HXHD200AY1B
VRV IV system indoor unit
4P513553-1 – 2017.11
"5.13. Field settings table"
(2), with the set value displayed to
button to change
button.
button to exit FIELD SET MODE.
button will discard the
INFORMATION
I
Before shipping, the set values have been set as
shown under
I
When exiting FIELD SET MODE, "88" may be
displayed on the remote controller LCD while the unit
initializes itself.
NOTICE
I
When running through the field settings you may
notice that there are some more field settings as there
are mentioned in the
page
19. These field settings are not applicable
and may not be changed!
I
For more information about installation related setting,
see installation manual of the indoor unit. For settings
different from the default value, contact your installer.
1
"5.13. Field settings table" on page
"5.13. Field settings table" on
Operation manual
19.
18