Domestic Water Heating Operation ( ); Automatic Storage - Daikin VRV IV HXHD125AV1B Operation Manual

Indoor unit
Table of Contents

Advertisement

Automatic setback function
Setback function provides the possibility to lower the room
temperature. The setback function can for instance be activated
during the night because the temperature demands during night and
day are not the same.
INFORMATION
I
Remark that the
operation.
I
By default the setback function is enabled.
I
The setback function can be combined with the
automatic weather dependent set point operation.
I
Setback function is an automatic daily scheduled
function.
The setback function is configured through field settings. Refer to
"5.12. Field settings" on page 18
one or more field settings.
I
[2-00] Status: defines whether the setback function is turned ON
(1) or OFF (0)
I
[2-01] Start time: time at which setback is started
I
[2-02] Stop time: time at which setback is stopped
I
[5-02] Leaving water setback temperature (temperature drop)
T
A
65°C
5°C [5-02]
B
60°C
[2-01]
A
Normal leaving water temperature set point
B
Leaving water temperature, including the leaving water setback
temperature
t
Time
T
Temperature
HXHD125AV1B + HXHD200AY1B
VRV IV system indoor unit
4P513553-1 – 2017.11
icon will be flashing during setback
for a detailed description how to set
t
[2-02]
5.4. Domestic water heating operation (
INFORMATION
Any domestic water heating operation is impossible when
the domestic hot water tank is not installed.
For the domestic water heating mode, several operations are
possible:
I
storage operation (either automatic or manually set)
I
reheat operation
I
disinfection operation
The purpose of each operation, and how the configuration is done, is
explained below.
Domestic water heating modes
T
A
B
D
E
F
G
A
Storage operation (if activated)
B
Reheat operation (if activated)
C
Disinfection operation (if activated)
Field settings
D
Disinfection operation temperature [5-00] (e.g. 70°C)
E
Hot water storage temperature [b-03] (e.g. 60°C)
F
Reheat maximum water temperature [b-01] (e.g. 45°C)
G
Reheat minimum water temperature [b-00] (e.g. 35°C)
t
Time
T
Domestic hot water tank temperature

Automatic storage

In this mode, the indoor unit will deliver hot water to the domestic hot
water tank based on the daily fixed pattern. This mode will continue
until the storage temperature set point is reached. During operation
of this mode, the
icon will be blinking with 1 second intervals.
Automatic storage is the recommended domestic hot water mode. In
this mode, water heats up during the night (when space heating
requirements are lower) until the storage temperature set point is
reached. The heated water is stored in the domestic hot water tank at
a higher temperature so it can fulfil the domestic hot water
requirements throughout the day.
INFORMATION
Remark that the
effective automatic storage operation. Presence of the
permanently lit
storage is enabled, but only means that reheat is enabled.
During operation it is always possible to cancel the
operation by pushing the
Be aware that after pushing the
that the permanently lit
)
C
t
icon will only be blinking during
icon does not mean that automatic
button once.
button, it is possible
icon still displays.