Summary of Contents for SWP Stealth DIGI-CUT 40PFC MV
Page 1
DIGI-CUT 40PFC MV Part No. 9030H OPERATOR’S MANUAL...
Page 2
STEALTH DIGI-CUT 40PFC MV IMPORTANT Read this Owner’s Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay particular attention to the safety instructions provided for your protection. Contact your distributor if...
STEALTH DIGI-CUT 40PFC MV CONTENTS SAFETY TECHNICAL INFORMATION INSTALLATION AND ADJUSTMENT 3.1 UNPACKING 3.2 INPUT POWER CONNECTIONS 3.3 GAS CONNECTIONS OPERATION CONTROL AND CONNECTORS 4.1 CUTTING PREPARATION 4.2 CUTTING OPERATION CUTTING GUN MAINTENANCE TROUBLESHOOTING MAIN ELECTRICAL DIAGRAM PARTS LIST...
OPERATION AND MAINTENANCE OF PLASMA ARC EQUIPMENT CA of cardiac pacemakers, hearing aids, or other electronic health equipment. Persons who work ne STEALTH DIGI-CUT 40PFC MV applications should consult their medical health professional and the manufacturer of the health HAZ- ARDOUS TO YOUR HEALTH.
Page 5
• Extra care must be taken when the workplace is moist or damp. STEALTH DIGI-CUT 40PFC MV • Ventilate all flammable or explosive vapors from the workplace. • Disconnect power source before performing any service or repairs.
STEALTH DIGI-CUT 40PFC MV TECHNICAL INFORMATION DIGI-CUT 40PFC MV Power Supply Voltage (V) 90 VAC~275 VAC Frequency (Hz) 50/60 1~110±10% 1~230±10% Rated input current (A) 34.5 22.6 Rated input power (Kw) Adjustment range of current (A) 20~30 20~40 Max no-load voltage (V)
STEALTH DIGI-CUT 40PFC MV INSTALLATION AND ADJUSTMENT Unpacking 3.1.1 Use the packing lists to identify and account for each item. 3.1.2 Inspect each item for possible shipping damage. If damage is evident, contact your distributor and / or shipping company before proceeding with the installation.
§4 Operation §4 Operation STEALTH DIGI-CUT 40PFC MV 4.1 Layout Of The Front And Rear Panel: 4.1 Layout Of The Front And Rear Panel OPERATION CONTROL AND CONNECTORS Fig 4.1 schematic drawing of the front panel and rear panel power pilot lamp: turn on power, the lamp on.
4.2 Cutting Preparation STEALTH DIGI-CUT 40PFC MV 1、Tightly connect the power cable to electrical socket outlet (the input voltage, refer to the secti Cutting Preparation parameters) 4.2.1 Tightly connect the power cable to an electrical socket outlet ( refer to the Input 2、connect the air pipe to the air supply equipment, the earth cable to the workpiece...
§5 Maintenance STEALTH DIGI-CUT 40PFC MV 5.1 Cutting gun maintenance CUTTING GUN MAINTENANCE WARNING 1. Check consumable parts for damage and replace if worn. Warning : 1. Check the consumable parts for damage, if worn, replace it. 2. Turn off the power source before check or remove cutting gun parts 2.
STEALTH DIGI-CUT 40PFC MV TROUBLESHOOTING WARNING There are extremely dangerous voltage and power levels present inside this unit. Do not attempt to diagnose or repair unless you have had training in power electronics measurement and troubleshooting techniques. 6.1 The cutting torch fails to ignite the arc when the torch is switched on and the TIP/ GUN/GAS light is on.
Page 12
STEALTH DIGI-CUT 40PFC MV No cutting output. Torch is activated, power source is on, gas flows and fan operates 6.7.1 Torch not properly connected to power supply – check that torch leads are properly connected to power supply.
STEALTH DIGI-CUT 40PFC MV PARTS LIST 9030H-02 COVER 9030H-03 FAN 9030H-05 AIR FILTER/REGULATOR 9030H-09 SOLENOID VALVE 9030H-15 FRONT PANEL 9030H-17 FEMALE TORCH CONNECTION 9030H-19 KNOB – USE 9000H-33 9030H-21 FRONT PCB 9030H-22 CONTROL PCB 9030H-24 RECTIFIER...
Need help?
Do you have a question about the Stealth DIGI-CUT 40PFC MV and is the answer not in the manual?
Questions and answers