NH-1SA-AC-BLU, NH-1SA-ACB-BLU Code Blue Station,
NHR-7A-CB1, NHR-7A-CB2 Code Blue Call Switch
The models listed above have been modified to allow the Blue Call button (NHR-7A-CB) to activate the highest
priority call on the NHX Nurse Call System. When the Blue switch is pushed down to the lower position, the master
station will indicate the call with a fast intermittent call tone and flashing LED. The call can be cancelled only by
raising the switch to the upper position. All other call levels remain the same.
WIRING DIAGRAM:
NHX-80X
11
12
Trunk line
13
output #1
14
15
16
21
22
Trunk line
23
output #2
24
25
26
PS-2420UL
A+
+
A-
-
+
B+
-
B-
PS-2420UL
NOTES:
1. The NH-1SA-ACB-BLU wires the same as the station shown above.
2. NHR-7A-CB1 is a Code Blue station includes one set of contacts (SPST).
3. The NHR-7A-CB2 model includes two dry contact closures (DPDT, BRN wires).
4. Black wire from NH-1SA-AC-BLU is only used in systems with All Call.
5. See operational instructions for the system following on page two of this instruction sheet.
6. Only wiring concerning the Code Blue stations is shown here. Please see standard Installation Manual
for complete information.
NH-1SA-ACB-BLU Instr
Page 1
- INSTRUCTIONS -
Brn
Red
Org
Yel
Grn
Blu
NHR-4A
Brn
Red
Org
NH-1SA-AC-BLU
Code Blue Sub
CN1:
Brn
Red
Org
Yel
Grn
Blu
CN2:
Brn
Red
Org
Yel
Yel
Grn
Grn
Blu
Blu
Blu
Pur
Gry
NHR-7A
Blk
Wht
Gry/Red
Models:
• NHR-7A-CB1: standard unit (SPST)
• *NHR-7A-CB2: Includes second dry
contact closure (DPDT)
Nurse Call System
0605
NHR-7A-CB1
Code Blue
Grn
Blu1
Yel
Blu(2)
Brn*
contact closure
Brn*
2nd dry

Advertisement

loading

Summary of Contents for Aiphone NHX NH-1SA-AC-BLU

  • Page 1 NH-1SA-AC-BLU, NH-1SA-ACB-BLU Code Blue Station, NHR-7A-CB1, NHR-7A-CB2 Code Blue Call Switch The models listed above have been modified to allow the Blue Call button (NHR-7A-CB) to activate the highest priority call on the NHX Nurse Call System. When the Blue switch is pushed down to the lower position, the master station will indicate the call with a fast intermittent call tone and flashing LED.
  • Page 2 4. To place a CODE BLUE CALL, activate the Code Blue Station located near the patient station by pulling the attached cord or sliding the blue call switch down. 5. To reset the CODE BLUE CALL, move the blue call switch to the upper position. Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005...

This manual is also suitable for:

Nh-1sa-acb-bluNhr-7a-cb1Nhr-7a-cb2Nhx