10. REPAIR
Before any repairs are undertaken please:
Stop fan in accordance to regulations and disconnect all poles from mains supply.
Wait until impeller is stationary.
Make sure that a restart is not possible.
Only use original spare parts manufactured and supplied by Breeze Fan.
Change of motor impeller:
Disconnect electrical supply in function box.
Remove louver.
Remove the fan casing in the wooden frame.
Unscrews and remove centrifugal casing and impeller.
Unscrews motor mounting and replace new motor.
Assembly fan.
Control whether installation is correct:
Motor and impeller must rotate freely
o
o Control whether
o Install maintenance cover if have.
The gap between impeller and casing must be regular.
o
Install the fan into air duct.
Push into operation after repaired.
Connect electric supply of motor.

11. TROUBLESHOOTING TABLE

PROBLEM
Ÿ
When switching on the
unit the fan does not
start.
Ÿ
Circuit breaker
tripping during the fan
start.
Ÿ
Low air flow.
Ÿ
Poor foundation
Ÿ
Fault installation
Ÿ
Low voltage
Ÿ
Contact between rotary
and stationary parts
Ÿ
Sucked in objects /
Adhere dust
Ÿ
Faulty ducting
Ÿ
Incorrect wiring
www.breeze.com.vn | breezefans@breeze.com.vn
direction of rotation is correct.
POSSIBLE REASONS
Ÿ
No power supply.
Ÿ
Motor jamming.
Ÿ
The automatic circuit breaker is
triggered by an abnormally high current
consumption due to a short circuit.
Ÿ
Clogging of air ducts or other ventilation
system elements. Impeller clogging.
Damaged air ducts. Air damper closure.
Ÿ
Excessive noise
Ÿ
Excessive vibration
Ÿ
Excessive noise
Excessive vibration
Ÿ
Insufficient air flow
Ÿ
Motor too hot
Ÿ
Excessive noise
Ÿ
Excessive vibration
Ÿ
Motor too hot
Ÿ
Excessive noise
Ÿ
Excessive vibration
Ÿ
Excessive noise
Ÿ
Excessive vibration
Ÿ
Insufficient air flow
Ÿ
Run abnormally
USER'S MANUAL
Fig 1
Fig 3
TROUBLESHOOTING
Ÿ
Check the electrical connections and the power
switch status.
Ÿ
Turn off the fan.
Ÿ
Troubleshoot the impeller jamming.
Ÿ
Restart the fan.
Ÿ
Disconnect the fan from power mains and
contact the Breeze Seller.
Ÿ
Do not turn on the fan again.
Ÿ
Clean the air ducts and other ventilation system
elements as well as the impeller.
Ÿ
Check the air ducts for damage.
Ÿ
Make sure the air dampers and louver shutters
are open.
Ÿ
Reinforce the foundation
Ÿ
Re-adjust the installation
Ÿ
Check power source
Ÿ
Inspect and adjust
Ÿ
Inspect and clean
Ÿ
Inspect and adjust
Ÿ
Change wiring