Page 1
We bring better air to life USER’S MANUAL DVS Series DVS 180 DVS 300 | DVS 500 DVS 780 | DVS 960 DVS 1200 | DVS 1900 | DVS 3000 SILENT INLINE FAN Thank you for choosing silent inline fan. Please read and save this user's manual for future reference.
USER’S MANUAL DVS SERIES We bring better air to life 1. GENERAL SAFETY INFORMATION Ÿ Please read the user’s manual carefully prior to installing and operating the unit. Ÿ This user’s manual is the primary operating document intended for technical, maintenance and operations staff.
DVS SERIES We bring better air to life 2. PRODUCTS OVEVIEW DVS series use a silent inline fan with high quality material and exceptionally super low noise design. The idea solution for medium demand ventilation in commercial and residential systems. Material: Ÿ...
USER’S MANUAL DVS SERIES We bring better air to life 4. PERFORMANCE PARAMETERS Max. Max. Power Current Speed Voltage Noise Air Volume Pressure Model (rpm/min) (V/P/Hz) (at 3m) (m /h) (Pa) DVS 180 0.11 1180 220/1/50 0.23 1140 220/1/50 DVS 300 0.45...
The equipment type and arrangement should be verified as ordered at once when it arrives at the jobsite. When a discrepancy is found, the local Breeze Sales Representative must be notified immediately so that corrective action may be investigated, also verify electrical conformance to specifications.
USER’S MANUAL DVS SERIES We bring better air to life Checks prior to initial start-up Proceed with the fan's initial start-up in the following sequence: • Check that the mechanical assembly has been carried out properly • Remove foreign bodies located in the suction and outflow areas and in the fan space •...
The automatic circuit breaker is Disconnect the fan from power mains and tripping during the fan triggered by an abnormally high current contact the Breeze Seller. start. Ÿ Do not turn on the fan again. consumption due to a short circuit.
Page 8
• Wait until impeller is stationary. • Make sure that a restart is not possible. • Only use original spare parts manufactured and supplied by Breeze Fan. Change of motor impeller: • Disconnect electrical supply in function box. • Unscrew motor mounting and pull out of the casing complete with motor, impeller.
Page 9
Applied standard: BREEZE INDUSTRIAL VENTILATION JOINT STOCK COMPANY Vietnam Singapore Head Office: Office: 215D8 Nguyen Van Huong Street, Thao Dien Ward, No 15, Yishun Industrial Street District 2, Ho Chi Minh City, Vietnam. 1, #03-29, WIN5 Singapore Tel: +84 28 6651 8585 | Hotline: +84 931 920 368 S768091.
Need help?
Do you have a question about the DVS Series and is the answer not in the manual?
Questions and answers