Download Print this page

Marco 5001862US Quick Start Manual

Advertisement

Quick Links

FRIIA COLD/SPARKLING
>
Sleek and stylish alternative
to bottled or POU water
>
Two font heights available
CHILLER/CARBONATOR
PRODUCT INFO
SIZE
NAME
DIMENSIONS
ORDER CODE
( D X W X H inches )
Chiller/
Carbonator
17.1 x 10.2 x 17.9
1001861US
A minimum operating pressure of 2 bar or 28 psi downstream of filter is required for optimum output l/min.
FRIIA CS
NAME
ORDER CODE
2b Font
1000868
2b Font Tall
1000869
ITEM
Fonts (all)
Chiller/Carbonator
For more information visit www.marcobeveragesystems.com
PERFORMANCE SPECS
CUPS
GAL/HR
/HR
7.9-11.8 GALS/hr based
175-235
on incoming water temp
(ΔT =
of 59°F and output water
18 °F)
temp of 41-44°F
FRIIA CS TALL
DIMENSIONS INC. DRIP TRAY
( D X W X H inches )
6.6 x 4.7 x 11.2
6.6 x 4.7 x 13.6
PACKAGING DIMENSIONS
(L x W x H inches)
11.4 x 22.4 x 8.4
19.2 x 11.8 x 20.2
ORDER CODES
(Complete bundle)
>
FRIIA CS
5001862US
>
FRIIA CS Tall
5001865US
SYSTEM SET - UP
PLUMBING, ELECTRICAL AND TECHNICAL SPECS
POWER
PLUMBING
COMPRESSOR
@110v
REQS
POWER
3/8"
Compression
180W
1/8hp
or 3/8" John
Guest
FONT DIMS
5.4"
DIMENSIONS EXCL. DRIP TRAY
( D X W X H inches )
5.4 x 1.1 x 11.2
5.4 x 1.1 x 13.6
WEIGHT
PLEASE
NOTE
4.4lbs
69.4lbs
CHARGE
REFRIGERANT
45g
R290
5.4"
TAP TO COUNTER
( inches )
9.7
11.8
FRIIA components (font
and chiller) are packed and
shipped in individual boxes.
FRIIA Sparkling variants
require food-grade CO
2
(not supplied by Marco).

Advertisement

loading

Summary of Contents for Marco 5001862US

  • Page 1 NOTE and chiller) are packed and shipped in individual boxes. Fonts (all) 11.4 x 22.4 x 8.4 4.4lbs FRIIA Sparkling variants require food-grade CO (not supplied by Marco). Chiller/Carbonator 19.2 x 11.8 x 20.2 69.4lbs For more information visit www.marcobeveragesystems.com...
  • Page 2 FRIIA C, FRIIA CS & FRIIA C HANDS - FREE FRIIA COLD, FRIIA COLD/SPARKLING & FRIIA COLD HANDS - FREE FRIIA C 5001860US FRIIA CS 5001862US COUNTER CUT - OUT WITH DRIP TRAY FRIIA C Tall 5001863US FRIIA CS Tall...
  • Page 3 FRIIA SYSTEM OVERVIEW COUNTER CUT - OUTS RADIUS OF MAXIMUM FONT PLACEMENT 1.25”/32mm Standard 31.5” high cabinet 4”/100mm For drip-tray only 23.6”/600mm CABINET OPERATING ENVIRONMENT Min: 31.5” (h) x 23.6” (w) x 23.6” (d) with 3.9” clearance around Cannot exceed temperature of 95°F machines all sides VENTILATION 10.4”/265mm...
  • Page 4 FRIIA PERFORMANCE & MAINTENANCE FRIIA OUTPUT VOLUME Based on flow rate of 0.3 GAL/min and ambient temperature of 68-77°F. Chart indicates FRIIA chilling capacity based on incoming water temperature and desired output water temperate. 13.2 11.8 10.5 82.4 °F) INCOMING TEMPERATURE ( Output Temp 37.4°F Output Temp 41°F Output Temp 44.6°F...

This manual is also suitable for:

Friia c tallFriia c hands-freeFriia csFriia cs tall5001860us5001863us ... Show all