Download Print this page

Graco DT 234140 A Repair Manual page 6

Airless paint sprayers

Advertisement

MOTOR WON'T OPERATE (Continued)
TYPE OF PROBLEM
Basic Electrical Problems
(continued)
Refer to wiring diagram on
page 13, to identify test
points (TP).
6
309712
Troubleshooting
WHAT TO CHECK
If check is OK, go to next check
5. That motor leads are securely fastened and
properly mated.
6. For loose motor brush lead connections and ter-
minals. See page 10.
7. Brush length which must be 1/2 in. minimum.
See page 10.
NOTE: Brushes do not wear at the same rate on
both sides of motor. Check both brushes.
8. For broken or misaligned motor brush springs.
Rolled portion of spring must rest squarely on
top of brush. See page 10.
9. Motor brushes may be binding in brush holders.
See page 10.
10.Motor armature commutator for burn spots,
gouges and extreme roughness.
See page 10.
11. Motor armature for shorts using armature tester
(growler) or perform spin test. See page 10.
1. Power supply cord (79). Connect volt meter be-
tween N (neutral) and TP1.
Plug in sprayer. Meter must read: 85–130 Vac.
Unplug sprayer.
2. ON/OFF switch (23). Connect volt meter be-
tween L and N terminal on ON/OFF switch. Plug
in sprayer and turn ON.
Meter must read 85–130 Vac
3. Motor thermal cutoff switch. Turn sprayer OFF.
Check for continuity between TO1 and TO2 with
ohmmeter.
4. All terminals for damage or loose fit.
WHAT TO DO
When check is not OK refer to this column
5. Replace loose terminals; crimp to leads. Be
sure terminals are firmly connected.
Clean circuit board terminals. Securely re-
connect leads.
6. Tighten terminal screws. Replace brushes if
leads are damaged. See page 10.
7. Replace brushes. See page 10.
8. Replace spring if broken. Realign spring with
brush. See page 10.
9. Clean brush holders. Remove carbon with
small cleaning brush. Align brush leads with
slot in brush holder to assure free vertical
brush movement.
10.Remove motor and have motor shop resur-
face commutator if possible. See page 18.
11. Replace motor. See page 18.
1. Replace power supply cord.
2. Replace ON/OFF switch. See page 12.
3. If thermal switch is open (no continuity), allow
motor to cool. If switch remains open after
motor cools, replace motor. If thermal switch
closes after motor cools, correct cause of
overheating.
4. Replace damaged terminals and reconnect
securely.

Advertisement