Dust/Chip Extraction - Bosch Professional GBH 2-26 DFR Original Instructions Manual

Hide thumbs Also See for Professional GBH 2-26 DFR:
Table of Contents

Advertisement

Changing the tool (SDS plus)
Inserting SDS plus application tools (see figure E)
The SDS-plus drill chuck enables you to change the applica-
tion tool easily and conveniently without needing to use ad-
ditional tools.
– GBH 2-26 DFR: Insert the SDS plus quick-change chuck
(2).
– Clean and lightly grease the shank of the application tool.
– Insert the application tool into the tool holder while turn-
ing it until it locks automatically.
– Check that it is locked by pulling on the tool.
As a requirement of the system, the SDS-plus application
tool can move freely. This causes a certain radial run-out at
no-load, which has no effect on the accuracy of the drill hole,
as the drill bit centres itself upon drilling.
Removing SDS-plus application tools (see figure F)
– Push the locking sleeve (5) back and remove the applica-
tion tool.
Changing the keyed chuck
GBH 2-26/GBH 2-26 RE/GBH 2-26 DRE
Inserting the Application Tool (see figure G)
Note: Application tools that do not have SDS plus must not
be used for hammer drilling or chiselling. Tools without SDS
plus and their drill chucks are damaged by hammer drilling
or chiselling.
– Insert a keyed chuck (19).
– Open the keyed chuck (19) by turning it until the tool can
be inserted. Insert the tool.
– Insert the chuck key into the corresponding holes of the
keyed chuck (19) and clamp the tool evenly.
– GBH 2-26 RE: Set the selector switch (16) to the
"drilling" symbol.
– GBH 2-26, GBH 2-26 DRE: Turn the impact/mode se-
lector switch (11) to the "drilling" position.
Removing the application tool
– Use the chuck key  to turn the sleeve of the keyed
chuck (19) anticlockwise until the application tool can be
removed.
Changing the keyless quick-change chuck
GBH 2-26 DFR
Inserting the application tool (see figure H)
Note: Application tools that do not have SDS plus must not
be used for hammer drilling or chiselling. Tools without SDS
plus and their drill chucks are damaged by hammer drilling
or chiselling.
– Insert the keyless quick-change chuck (1).
– Hold the retaining ring (23) of the keyless quick-change
chuck firmly in place. Open the tool holder by turning the
front sleeve (22) until the tool can be inserted. Hold the
retaining ring (23) in place and firmly tighten the front
sleeve (22) by turning it in the direction of the arrow until
you hear it click into place.
– Check that it is seated securely by pulling on the tool.
Bosch Power Tools
Note: If the tool holder was unscrewed all the way, a scrap-
ing sound may be heard while retightening the tool holder
and it may not fully tighten.
In this case, turn the front sleeve (22) in the opposite direc-
tion to the arrow by one full turn. This will allow the tool
holder to be fully tightened.
– Turn the impact/mode selector switch (11) to the
"drilling" position.
Removing the application tool (see figure I)
– Hold the retaining ring (23) of the keyless quick-change
chuck firmly in place. Open the tool holder by turning the
front sleeve (22) in the direction of the arrow until the
tool can be removed.

Dust/Chip Extraction

The dust from materials such as lead paint, some types of
wood, minerals and metal can be harmful to human health.
Touching or breathing in this dust can trigger allergic reac-
tions and/or cause respiratory illnesses in the user or in
people in the near vicinity.
Certain dusts, such as oak or beech dust, are classified as
carcinogenic, especially in conjunction with wood treatment
additives (chromate, wood preservative). Materials contain-
ing asbestos may only be machined by specialists.
– Use a dust extraction system that is suitable for the ma-
terial wherever possible.
– Provide good ventilation at the workplace.
– It is advisable to wear a P2 filter class breathing mask.
The regulations on the material being machined that apply in
the country of use must be observed.
Avoid dust accumulation at the workplace. Dust can
u
easily ignite.
Dust extraction with GDE 16 Plus (accessory)
(see figure J)
For dust extraction, the GDE 16 Plus (accessory) is re-
quired.
The dust extractor must be suitable for the material being
worked on.
When extracting dry dust or dust that is especially detri-
mental to health or carcinogenic, use a special dust ex-
tractor.
Dust collection cap (accessory) (see figure K)
To collect dust easily without using extraction, a dust collec-
tion cap (25) is required.
Dust Extraction with GDE 18V-26 D (accessory)
For dust extraction, the GDE 18V-26 D dust extraction at-
tachment (accessory) is required.
Observe the information on intended use in the relevant op-
erating manual when using the GDE 18V-26 D.
English | 11
1 609 92A 7W2 | (22.08.2022)

Advertisement

Table of Contents
loading

Table of Contents